Outputs Wgm-B; Outputs Wgm-R / Wgm-D - Bosch Rexroth WGM Operating Instructions Manual

Oil humidity sensor
Table of Contents

Advertisement

Analog output
Tolerance
Load Ω
Switching output
PNP switching output
Switching current
Temperature
measurement
Measurement range
Accuracy
Analog output
Tolerance
Load Ω

9.4 Outputs WGM-B

Version
2A1S
Connector (base)
1 x M12 – 8-pin
Switching output
X
(fixedly set)
IO-Link
Analog output for
X
humidity
Analog output for
X
temperature

9.5 Outputs WGM-R / WGM-D

Version
2A2S
Connector (base)
1 x M12 – 8-pin
Display & remote
Sensor connection
1 x M12 – 8-pin
socket (bottom) remote
Switching outputs
2 x
IO-Link
Analog output for
X
humidity
Analog output for
X
temperature
Selectable current or voltage output
(4 - 20 mA, 2 - 10 V, 0 - 10 V or 0 - 5 V)
± 0.5% FS
= (U
- 8 V) / 0.02 A
B
Selectable switching function and switching output
max. 0.2 A per output
-20 °C to +120 °C
± 1.5 % FS
Selectable current or voltage output
(4 - 20 mA, 2 - 10 V, 0 - 10 V or 0 - 5 V)
± 0.5% FS
= (U
- 8 V) / 0.02 A
B
Appendix
1D0S
1 x M12 – 4-pin
X
1D1S
1 x M12 – 4-pin
1 x M12 – 8-pin
1 x
X
RE 51550-B/09.2019, Bosch Rexroth AG
39/46

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents