9.2 Technical data WGM-B

Sensor option WGM-B
Ambient temperature
Supply voltage (U
)
B
Material / version
Housing
Material in contact with
media
Weight
Protection class
* with fitted plug-in connector
IO-Link
IO-Link
Baud rate
SIO mode
Min. cycle time
Humidity measurement
Measurement range
Accuracy
Analog output
Tolerance
Load Ω
Switching output for humidity
PNP switching output
1)
Switching current
1)
Others on request
Temperature
measurement
Measurement range
Accuracy
Analog output
Tolerance
Load Ω
-20 °C to + 70 °C
18 – 30 V
(nominal voltage 24 V DC)
Stainless steel/aluminum
1.4301, 1.4571, 2.4478, FR4, glass
approx. 205 kg
IP67*
Revision 1.1
COM2 (38.4 k)
Yes
20 ms
0 - 100% rel. humidity
± 3 % FS
4 - 20 mA (0 - 100% relative humidity)
± 0.5% FS
= (U
- 8 V) / 0.02 A
B
Permanently set to 80% relative humidity
max. 0.2 A
-20 °C to +120 °C
± 1.5 % FS
4 - 20 mA (-20 to +120 °C)
± 0.5% FS
= (U
- 8 V) / 0.02 A
B