4.9.5

Input Characteristic Curve

4.9.6

Digital Outputs

4.9.7

Actuator Selection Specifications

4.9.8

Effect of Operating States

Input voltage U
N
0 V
5 V
15 V
24 V
30 V
Tab. 4-9:
Input characteristic curve
Number of outputs
Connection type
Termination technique
Output voltage
Output current (per channel)
Voltage drop against U
at 200 mA
A
Output current (module)
Leakage current when switched off
Output circuit
Tab. 4-10:
Digital outputs
Front-end processing time 90% (hard‐
ware)
Edge steepness T
ON/OFF
Front-end jitter/skew
Load type
Switching frequency
Type of protective circuit
Tab. 4-11:
Actuator selection
CPU stop of PLC
Field bus interruption
Bosch Rexroth AG
Device Description
Typical input current
0 mA
2.0 mA
2.5 mA
2.9 mA
3.2 mA
4 (0 ... 3)
4 shielded M12 male connector,
A-coded, 4-pin
2- to 3-wire
≤ U
A
0.2 A
Short-circuit/overload proof (thermal
shutdown)
Maximum 2,0 V DC
Max. 0.8 A (signals) + max. 1 A (supply)
Typically 100 µA
Push/Pull
Max. 0.5 μs
Typ. < 0.2 μs
≤ 0.2 μs
Inductive, ohmic loads and lamp load
Inductive load: Upon request
Ohmic load: Upon request
Lamp load: Upon request
External protection (e.g. free-wheeling di‐
odes)
Acc. to substitute value strategy
Acc. to substitute value strategy