10.1

General characteristic data

Submenu
Settings/adjustment
range
Screensaver display
None
Boiler temperature
Outside temperature
Date
Time
Screensaver
1...15...120 min
activation after
Language
Date format
Date
Time
Time zone
Europe/Berlin
Europe/London
Europe/Paris
Europe/Moscow
UTC
GMT
Minimum Outside
−50...-10...0 °C
temperature
Building type
Light
Middle
Heavy
Insulation standard
Small
Middle
Good
Table 5 General characteristic data menu
10.2

Module configuration

When the control unit is switched on or after a reset, the modules are
automatically recognised and their information downloaded.
If the modules are not recognised automatically:
▶ Set the modules manually.
Submenu
Slot 1...4
Table 6 Menu Module configuration
Control 8310 – 6720856493 (2022/07)
Explanation
Select whether a screensaver should be
displayed, and if so, which one
Time that elapses from when the display was
last touched until the screensaver is displayed
Selection of language of texts displayed
Selection of date format
Entry of date
Entry of time
Selection of time zone
Abbreviation for the world time
Abbreviation for Greenwich Mean Time
The minimum outside temperature is the
average of the coldest outside temperatures
recorded in previous years.
Low thermal storage capacity,
e. g. prefabricated building, wood framing
Average thermal storage capacity,
e g. house made of hollow blocks
High thermal storage capacity,
e. g. house made of blocks
No or minimum insulation effect, e.g. house
without insulation
Medium insulating effect, e.g. house with
10 cm mineral wool
Large insulating effect, e.g. new build or
renovated house with 20 cm mineral wool
Settings/adjustment range
None
Module configuration
Note
Set during commissioning by the Commissioning
wizard.
Regional zone where the same time applies.
Set during commissioning by the Commissioning
wizard.
▶ Obtain the regional average minimum outside
temperature values from the description of the
master control unit.
▶ Match heating system to the construction
( description of the master control unit).
▶ Match heating system to the insulation standard
( description of the master control unit).
Explanation
The installed modules can be
selected from a list.
Menu structure
Remark
Slots for function modules and
auxiliary modules