5.1.1.6

Troubleshooting

Error detection
Device does not respond, all LEDs are
off
The red LED (POWER) flashes once
per second.
The yellow LED (RADIO) is off.
5.1.2
Installation & Operation
5.1.2.1

Notes on installation

Before you install the devices, read this section carefully to ensure trouble-free installation and
operation.
The devices can only be used in conjunction with the RTLS localization system. Setup,
installation and use of the tools and clients of the RTLS localization system are described in the
corresponding manuals.
The device is intended for fixed installation on walls or ceilings. Installation is to be performed
by qualified and trained personnel according to the operating instructions. In addition,
installation must take place in accordance with the respective instructions for the installation of
electrical systems and utilities. The devices must be installed so that they are accessible for
future maintenance, e.g., for opening the enclosure cover.
Note the specifications in the section "Technical specifications" during installation and
operation. Ensure that all screws are securely and firmly screwed into the wall / ceiling and can
support the weight of the device and its wiring.
Make sure that the ambient temperature does not exceed 50 °C and that the device is not
installed at a location where it is exposed to direct sunlight.
Connection of the cables
Make sure that the Twist-Lock connectors are inserted correctly to prevent moisture from
entering the enclosure.
Make sure that the wiring is correct before you start up the device.
Only use the cables described in the manual, supplied with the device or otherwise prescribed.
SIEMENS AG is not liable for damages or functional limitations caused by the use of other
cables.
Protect the device from penetrating moisture by closing off connectors that are not in use with
suitable covers. These covers are installed on the device.
Supply voltage
The device can be operated with a DC voltage of 8 to 30 volts.
System Manual, 04/2019, C79000-G8976-C577-01
Cause of the error
The device is not connected or the pow‐
er supply unit is not switched on.
Undervoltage on the device
Device is not connected to the Locating
Manager.
5.1 SIMATIC RTLS4030A

Troubleshooting

Check the supply voltage of the device.
Check the supply voltage of the device.
Switch on Locating Manager.