Siemens SIMATIC RTLS Operating Instructions Manual

Localization systems
Hide thumbs Also See for SIMATIC RTLS:

Advertisement

Quick Links

SIMATIC RTLS PCB OEM AC
SIMATIC RTLS
Localization systems
SIMATIC RTLS PCB OEM AC
Operating Instructions
03/2020
C79000-G8976-C519-03
Introduction
Device description
Installation & Operation
Technical specifications
Approvals
1
2
3
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RTLS

  • Page 1 SIMATIC RTLS PCB OEM AC Introduction Device description Installation & Operation SIMATIC RTLS Technical specifications Localization systems SIMATIC RTLS PCB OEM AC Approvals Operating Instructions 03/2020 C79000-G8976-C519-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Pin assignment ........................10 LED status indicator ........................ 10 Dimension drawing ......................... 11 Installation & Operation ......................... 13 Notes on installation........................ 13 Cleaning and maintenance ..................... 13 Technical specifications ........................15 Approvals .............................. 17 SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 4 Table of contents SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 5: Introduction

    Further documentation The system manual "Commissioning SIMATIC RTLS" provides information on other SIMATIC RTLS products that you can operate together with the devices in this product line in an Industrial Ethernet network. You can find the system manual at the following link: (https://support.industry.siemens.com/cs/us/en/ps/25277)
  • Page 6 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
  • Page 7 Introduction To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under: (https://support.industry.siemens.com/cs/us/en/ps/15247/pm) Recycling and disposal The products are low in harmful substances, can be recycled and meet the requirements of the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE).
  • Page 8 Introduction SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 9: Device Description

    The RTLS transponder can be damaged by electrostatic discharge (ESD). Take suitable precautionary measures when unpacking and operating the transponder to avoid damage. Order data RTLS PCB OEM AC Table 2- 1 Order data RTLS PCB OEM AC Article number SIMATIC RTLS PCB OEM AC 6GT2700-8DF00-0AX1 6GT2700-8DF10-0AX1 CMIIT 6GT2700-8DF20-0AX1 6GT2700-8DF30-0AX1...
  • Page 10: Pin Assignment

    Flashes green every three seconds when the transponder is active Is off when the transponder is inactive Green and red LEDs light up for 1 second on system start Flashes green every 0.1 seconds after a watchdog reset SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 11: Dimension Drawing

    Dimension drawing The UWB antenna is arranged diagonally standing up on the top side of the PCB. Figure 2-1 Dimension drawing SIMATIC RTLS PCB OEM AC - All dimensions specified in millimeters SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 12 Device description 2.5 Dimension drawing SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 13: Installation & Operation

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
  • Page 14 Installation & Operation 3.2 Cleaning and maintenance SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 15: Technical Specifications

    Technical specifications Table 4- 1 Technical specifications of the transponder RTLS PCB OEM AC 6GT2700-8DF00-0AX1, 6GT2700-8DF10-0AX1 6GT2700-8DF20-0AX1, 6GT2700-8DF30-0AX1 Product name SIMATIC RTLS PCB OEM AC PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2011 UWB Transmission speed 850 kbit/s Operating frequency rated value 3993.6 MHz (UWB channel 2;...
  • Page 16 Dimensions of board (L x W x H) 25 x 25 x 18 mm Dimensions of antenna (L x W x H) 20.6 x 12.7 x 1.6 mm Weight Degree of protection IP00 SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 17: Approvals

    (0 Hz - 300 GHz) The products described in these operating instructions meet the requirements of EU directive 2014/30/EU "Electromagnetic Compatibility" according to the designated standards for the following areas of application. SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 18 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments ● EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...
  • Page 19 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM AC (6GT2700-8DF10-0AX1); FCC ID NXWOEMAC This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:...
  • Page 20 In order to comply with FCC RF Exposure requirements, this device must be installed to provide at least 20 mm separation from the human body at all times. IC information Siemens SIMATIC RTLS PCB OEM AC (MLFB 6GT2700-8DF30-0AX1); IC ID 267X- OEMAC This device complies with Industry Canada license-exempt RSS standard(s). Operation is...
  • Page 21 Pour être conforme aux exigences de la ISED relatives à l'exposition aux radiofréquences, ce matériel doit être installé de manière à assurer à tout moment une distance d'au moins 20 mm du corps humain. SIMATIC RTLS PCB OEM AC Operating Instructions, 03/2020, C79000-G8976-C519-03...

Table of Contents