Transponder
7.7 SIMATIC RTLS PCB OEM AX
Operating frequency rated value
Transmit power
Range
Accuracy of the localization
Antennas
PHASE radio frequencies (data transfer and optional locali‐
zation)
Wireless method
Transmission speed
Operating frequency rated value
Transmit power
Range
Accuracy of the localization
Antennas
Bandwidth
Supply voltage, power consumption
Supply voltage
Energy intake
Permitted ambient conditions
Ambient temperature
Design, dimensions, weights and connectors
Dimensions (L x W x H)
Weight
Degree of protection
7.7.4
Approvals
You can find the current EU Declaration of Conformity for these products on the Internet at
Siemens Industry Online Support.
Link:
dtp=Certificate&mfn=ps&pnid=14970&lc=en-US)
178
(https://support.industry.siemens.com/cs/products?
3100 MHz ... 4800 MHz
6000 MHz ... 7000 MHz
0.037 mW (-41.3 dBm/MHz)
Max. 30 m
0.2 m
UWB antenna integrated
IEEE 802.15.4
1 Mbps
2.40 ... 2.48 GHz ISM band
Max. 4 dBm (can be set)
Max. 50 m
1 m
2.4 GHz antenna integrated
2 MHz; data transmission on 802.15.4; channels can be set
5 V DC (±100 mV)
Max. 1 A (including scanner)
0 to +50 °C
32.5 x 62 x 18.6 mm
Approx. 9 g
IP00
System Manual, 04/2019, C79000-G8976-C577-01
6GT2700-8DF00-0AX0