10.8 4TXK6524G1000AA failure code
LED flash
times of
Indoor
Contents of Malfunction
outdoor
display
PCB
15
E7
Communication fault
--
E1
Sensor fault
E2
Sensor fault
--
--
E4
EEPROM ERROR
--
E14
Fan motor fault
1
F12
EEPROM ERROR
2
F1
IPM protection
3
F22
Overcurrent fault
4
F3
Communication fault
6
F19
Power fault
8
F4
High Td temperature
9
F8
DC fan motor fault
10
F21
Te fault
11
F7
Ts fault
12
F6
Tao fault
13
F25
Td fault
18
F11
Compressor fault
19
F28
Detection loop fault
24
F2
Overcurrent protection
25
F23
Overcurrent protection
Diagnosis and Analysis
Communication fault between indoor and outdoor units
Room temperature sensor fault
Heat-exchange sensor fault
Indoor EEPROM error
Indoor fan motor malfunction
Outdoor EEPROM error
The protection of IPM
Overcurrent protection of AC electricity for the outdoor model
Communication fault between the IPM and outdoor PCB
Power voltage is too high or low
Overheat protection for discharge temperature
Outdoor DC fan motor fault
Defrost temperature sensor fault
Suction temperature sensor fault
Ambient temperature sensor fault
Discharge temperature sensor fault
Compressor abnormal running
Loop of the station detect error
Overcurrent of the compressor
Overcurrent protection for one phase of the compressor
149