Install insunlation for the drain pipe
Cut the included insulation material to an appropriate size and adhere it to the pipe .
Drain pipe insulation (acessories)
Indoor unit (drain port)
Electrical Wiring
A. Connect wiring to the terminals
(3) Connect the wiring
B. For solid core wiring (or F-cable)
(1) Cut the wire end with a wire cutter orwire-cutting pliers, then strip the insulation to about 15/16"(25mm) to
expose the solid wire .
(2) Using a screwdriver, remove the terminal screw(s) on the terminal board .
(3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw .
(4) Shape the loop wire properly, place it on the terminal board and tighthen securely with the terminal screw using
a screwdriver .
C. For strand wiring
(1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation to about 3/8"(10mm) to expose
the solid wire .
(2) Using a screwdriver, remove the terminal screw(s) on the terminal board .
(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end .
(4) Position the round terminal wire, and replace and tighten the terminal screw using a screwdriver .
Drain pipe
Insulation for Drain pipe (To be
.
obtained locally
Lenght should be at least 8 mm
(1) Remove the screw
Remove the screw
Indoor unit
No gap
8 2
Drain pipe insulation
Drain pipe
10 mm or over