For single phase power supply models:
4TXK6524G1000AA,4TXK6536G1000AA
4TXK6512G1000AA,4TXK6518G1000AA
Power supply cable: H05RN-F 3G 4 .0mm 2 4TXK6548G1000AA, 4TXK6560G1000AA Power supply cable:
H05RN-F 3G
6 .0mm 2 Indoor and outdoor connection cable: H05RN-F 4G 2 .5mm 2 (* 1 Note: If the indoor and outdoor unit
connection cable length L satisfied condition 40m< L<55m, please change the connection cables specification to
H07RN-F 4G
4 .0mm 2 . If the indoor and outdoor unit connection cable length L satisfied condition 55m≤L≤75m, please change
the connection cables specification to H07RN-F 4G 6 .0mm 2 )
 Fix the cable with the clip to prevent slide .
50/60Hz
Clip
Outdoor-indoor unit
connection cable
Clip
Power supply cable