Operating Parameters; Using The Set Command To Turn Display Of Meters On Or Off; Table 24 - Nortel Meridian 1 Manual

Background terminal facility
Table of Contents

Advertisement

Operating parameters

Table 24

Using the Set command to turn display of meters on or off

SEt MEter 2703 DIsplay (ON) <CR>
SEt MEter 5001 5035 DIsplay OFf <CR>
SEt MEter ALl DIsplay (ON) <CR>
For a group of consecutive DNs, the second DN entered must be a higher
number than the first.
You may not be able to SEt all DNs at once if the ALl option is not on (see
"Define options for the Set command" on page 17).
You may not be able to SEt a group of consecutive DNs if the RAnge option
is not on (see "Define options for the Set command" on page 17).
You can use X substitution if it is allowed (see "Define options for the Set
command" on page 17). For example, SEt MEter X01 DIsplay OFf will turn
off meter display for DN 1001, 2001, 3001, 4001, ... 9001.
You can combine this command with setting a meter value by putting DIsplay
ON, or OFf, at the end. For example, SEt MEter 1023 VAlue 10 DIsplay
OFf will set the value of DN 1023's meter to 10 and turn off the display of
meter changes for DN 1023. Do not combine it with turning a meter on or off.
Message Registration
Meter for one DN—display turned on for DN 2703.
Meters for a group of consecutive DNs—display
turned off for DN 5001 to 5035.
Meters for all DNs—display turned on for all DNs.
Background Terminal Facility
Page 83 of 120
Description