Irregular Hip/Valley and Jack Rafters — Ascending, with Jacks
Mating at Hip/Valley
You're working with a 7/12 Pitch and half your overall span is 4 Feet.
The Irregular Pitch is 8/12, and the Jacks need to mate at the Hip.
The maximum allowable On-center spacing is 16 Inches. Find the
Jack rafter sizes from smallest to largest (ascending order).
Complete the following steps:
(1) Set Preference display to "JK ASCEND" (Jack sizes in
ascending order);
(2) Set Preference display to "IRJK JAC-JAC" (Jacks mate);
(3) Find the length of the common rafter;
(4) Find the length of the adjoining "Irregular" Hip (or Valley) and
the cut angles;
(5) Find the o.c., incremental jack adjustment, Jack lengths and
cut angles on the "Irregular" pitched side;
(6) Find the o.c., incremental jack adjustment, Jack lengths and
cut angles on the "Regular" pitched side.
Note: After completing this example, you may need to reset the Preferences back to
"IRJK OC-OC" if you do not normally figure jacks in this manner. (See Preference
Settings on page 83.)
KEYSTROKE
1. Review Preferences until you find "Jack Descend":
o o
Ç ß (Prefs)
(If not at 1/16, press + until 1/16 is displayed)
ß
ß
ß
ß
ß
ß
Set Preference to "Ascend":
+ (plus sign)
2. Set Preference to "Jacks Mate":
ß
+ (plus sign)
3. Find common rafter length:
7 i p
4 f R
d
64 — C
ONSTRUCTION
M
®
P
/ T
ASTER
RO
FRAC 0-1/16
HDRM 6
RAKE dESCEnd
JACK dESCEnd
JACK ASCEnd
RUN 4
DIAG 4
/ D
RIG
ESKTOP
DISPLAY
0.
INCH
AREA Std.
VOL Std.
8
FEET
INCH
AW outSidE
IRJK OC-OC
IRJK JAC-JAC
PTCH 7
INCH
0
FEET
INCH
7-9/16
FEET
INCH
(Cont'd)