Configuration Parameters Of The Applicator - CAB 4414 Series Service Manual

Stroke applicator
Hide thumbs Also See for 4414 Series:
Table of Contents

Advertisement

7
Configuration
32
Configuration Parameters of the Applicator
7.2
 Start menu.
 Select
Parameter
Transfer mode
Cycle sequence
Waiting position
Blow time
Support delay on
Support delay off
Start delay
Lock time
Vacuum delay
Vacuum control
Label hand-over
Cleaning blow
Peel-off position
Table 4
Setup >
Labelling.
Meaning
Setting the operation mode Stamp on, Roll on, Blow on
Setting the application mode Print-Apply / Apply-Print
Print-Apply:
An external start signal releases the print of a label and following the
application of the label. After a cycle is complete, the pad without label
waits in the start position.
Apply-Print:
An extra signal starts the print of the first label and the transfer of the
label to the pad. The external start signal releases the application of the
label and following the print and transfer of the next label.
After a cycle is complete, the pad with a label is in the waiting position.
¾ Only at Transfer mode = Blow on and Cycle sequence = Apply-Print
up: Pad waits in the start position for the start signal
down: Pad waits in the labelling position for the start signal
¾ Only at Transfer mode = Roll on
Switch-on time (max. 2,5 s) of the blowing air for the label transfer
Setting the switch-on delay (max. 2,5 s) for the supporting air between
print start and switching on the supporting air. The delay prevents
swirling at the front of the label and, consequently, avoids faults when
the label is being picked up from the printer.
Setting the switch-off delay (max. 2,5 s) for the supporting air between
the end of label forwarding and switching on the supporting air. The
delay can be useful to separate the rear edge of the label from the
carrier to avoid errors and to improve the accuracy of label positioning
Delay (max. 2,5 s) between start signal and the start of an labelling
cycle.
Allows e.g. the use of product sensors at conveyors.
All start signals coming in following the first start signal are ignored when
they arrive within the lock time (max. 2,5 s).
On - The vacuum will be switched on after the label feed is completed.
Off - The vacuum will be switched on when the label feed starts.
Setting the label transfer check from printer to pad and from pad to
product by the vacuum sensor
Passive - The pad waits in front of the dispense edge for the label.
Active - The pad moves to the dispense edge and takes the label.
Activation of a short blow impulse after the application of the label to
clean the suction channels.
Shift the position of the dispensed label relative to the dispensing edge.
The setting can also be adjusted by the software.
The settings of configuration and software are added together.
Parameters of the Setup > Labelling menu
32
Default
Stamp on
Print-Apply
up
1000 ms
0 ms
0 ms
0 ms
0 ms
Off
On
Passive
Off
0.0 mm