6
Adjustments
6.12

Lift Speed of Cylinder X/Y

1
Fig. 33
One-Way Flow Control Valve on Cylinder X/Y
 Adjust lift speed as necessary.
 To push the movement out in X-direction turn the screw on throttle valve (1) counterclockwise. turning clockwise
on throttle valve (1) reduces the speed (move out) in X-direction.
 To push the movement out in Y-direction turn the screw on throttle valve (2) counterclockwise. turning clockwise
on throttle valve (2) reduced the speed (move out) in Y-direction.
 To push the movement in Y-direction turn the screw on throttle valve (3) counterclockwise. turning clockwise on
throttle valve (3) reduced the speed (move in in Y-direction.
6.13

Sensors on Cylinder X/Y

2
1,7 mm
z
x
z
y
x
Fig. 34
Sensors on cylinder X/Y
y
2
3
1
11 mm
y
3
4
z
x
Place sensor start position(2) cylinder X so that it
switched on in case the cylinder X (1) is full moved
in and switched off if the cylinder leaved this
position.
Factory setting: 1.7 mm outwards from the front
edge of the cylinder to the edge of the sensor on
the cable.
Place sensor end position (4) cylinder Y so that
the sensor will switch on if the cylinder Y (3) is
completely moved out and will switch off if the
cylinder leaved this position.
Factory setting: 11 mm inwards from the front edge
of the cylinder to the edge of the sensor on the
cable.