Adjustments; Adjusting The Pad - CAB 4414 Series Service Manual

Stroke applicator
Hide thumbs Also See for 4414 Series:
Table of Contents

Advertisement

6

Adjustments

6.1

Adjusting the Pad

For the perfect application of labels it is necessary that the pad is placed precisely above the dispensed label.
Aligning the pad parallel to the dispensing plate
The edge of the pad should be positioned parallel to the dispensing plate of the printer in order to position the label
exactly on the pad.
1
Fig. 13
Aligning the pad to the dispensing plate
1. Loosen the knurled screw (3) and the set screw (4).
2. Screw in the knurled screw (3) until the pad edges (5) are aligned parallel
to the dispensing edge (6) of the printer.
3. Tighten the set screw (4) until it touches the printer.
Aligning the pad at an angle to the dispensing plate
4. If the angle between the pad surface and the dispensing edge - support surface is not 0 ° loosen screw (2).
5. Correct the angle of attack by turning the eccentric (1).
6. Tighten screw (2).
2
3
4
z
y
5
x
A
B
6
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

4414l-2004414l-3004414l-4004414r-2004414r-3004414r-400

Table of Contents