Labelling Position Of The Tamp - CAB 4414 Series Service Manual

Stroke applicator
Hide thumbs Also See for 4414 Series:
Table of Contents

Advertisement

6
Adjustments
24
Measuring Point Support Air (MP S) of support air
Fig. 23
Reading points to measure the pressure
!
Attention!
After pressure measurements, connect all component exactly and check it.
6.6

Labelling Position of the Tamp

The labelling position is depend of the customer environment and must adjust finally on-site.
Fig. 24
Adjusting the labeling position
1
2
3
MP S
z
1
2
Use a manometer with a measurement area -7 to 7 bar for
measurement the pressure.
MP S : support air (reference value 2 bar)
1. Remove cover and connect the manometer on RP S.
- Tube (2) from valve block to blow tube connector.
- Fitting (3) on the blow tube.
2. Activate the valve manually with open compressed air
supply and pressing of micro switch (1) to measure the
pressure.
3. As and when required adjust it on support air throttle valve
"support air" .
4. Mount cover again.
The labelling position of the tamp is different to the start
position in X- and Y-direction and will adjust by setting screws
in both directions.
With the setting screws is a positioning space up to +/- 2 mm
possible.
y
Setting in Y-direction by setting screw (1) .
x
Setting in X-direction by setting screw (2) .
24