Cleaning The Pellet Container; Checking Bearings; Checking Seals; Cleaning The Flue Pipes - RIKA PRIMO RAO Operating Manual

Hide thumbs Also See for PRIMO RAO:
Table of Contents

Advertisement

Cleaning the pellet container

Do not refill the completely empty container immediately; remove
the residues (dust, chippings etc�) from the empty container� The unit
must be disconnected from the mains!

Checking bearings

(annually)
All built-in bearings (pellet screw) should be checked� Clean or
replace bearings depending on condition�

Checking seals

(annually)
Check the condition of the seals at least once a year� Repair or
replace seals depending on condition�
Note
Only intact seals ensure your stove works perfectly!
Tip
You will find the seals and sealing kit in the spare part overview�

Cleaning the flue pipes

(annually)
Remove the flue pipes� Inspect and clean the chimney connection�
Brush off any soot and dust deposits in the fire and in the flue pipes
and vacuum�
Note
Accumulated fly ash in the flue gas channels may impair the
performance of the stove and pose a safety risk�

Reset - Cleaning interval

Note
A reset can only be carried out if the stove temperature is below
80 °C!
After you have cleaned and reassembled the stove properly, you
must perform a reset�
Restore the power supply and switch on the stove�
Wait until all POWER LEDs are continuously lit yellow�
Reset: Press and hold the
OPERATION BUTTON
Press and hold the OPERATION BUTTON for 2 seconds to reset the
cleaning interval�
The stove can now be put back into operation�
for 2 seconds