Cleaning the convection air openings
Vacuum clean any dust deposits from the convection air openings at regular
intervals.
The stove should be cleaned thoroughly prior to the start of the heating season
to prevent excess odour.
Combustion air - intake
If necessary, please also clean the air intake with a hoover.
Note
Only when the stove is cold! You could vacuum out embers – FIRE RISK!
Cleaning the pellet container
Do not refill the completely empty container immediately; remove the residues
(dust, chippings etc.) from the empty container. The unit must be disconnected
from the mains!
Cleaning the flue gas channels
annually
Remove the flue pipes. Inspect and clean chimney connection. Brush off any
soot and dust deposits in the fire and in the flue pipes and vacuum.
Note
Accumulated fly ash in the flue gas channels may impair the performance of
the stove and pose a safety risk.
Checking door seal
annually
The condition of the seals at doors and glass should be checked at least 1 x per
year. Repair or replace seals depending on condition.
Note
Only intact seals ensure your stove works perfectly.
Bearings
annually
All built in bearings (pellet screw, turning grid) should be checked. Clean or
replace bearings depending on condition.