17. MAINTENANCE

The frequency with which the stove requires cleaning and the
maintenance intervals depend on the fuel you use� High moisture
content, ash, dust and chips may more than double the maintenance
required� We would like to point out again that only tested and
recommended pellets may be used as fuel�
Note
Ash may contain embers – only place ash in sheet steel containers�
FIRE RISK! In a cold state, dispose it of in the household waste�
Note
We recommend at least once a year to have all maintenance
carried out by your RIKA dealer�

Cleaning painted surfaces

(If necessary)
Wipe the painted surfaces with a damp cloth, do not scrub� Do not
use solvent-containing cleaners�

Open the combustion chamber door

To open or close the combustion chamber door use the included key�
This key can be stored on the back of the stove when not in use�

Cleaning the door glass

(If necessary)
The viewing window becomes coated in the case of solid fuels,
particularly with the very fine ash of wood pellets, light or dark
depending on the pellet quality (especially with low output)� The
glass can be cleaned best with a moist cloth� Stubborn dirt can be
removed with a special cleaner available from your stove dealer�
Usual cleaners containing acid or solvents can be too harsh and
damage the glass�

Cleaning the flame temperature sensor

Remove the dust deposits from the sensor at regular intervals� Use a
clean cleaning cloth or newspaper�

Cleaning of the burn pot

(1x daily)
Make sure that the air vents are not blocked with ash or clinker�
Remove the clinker using the supplied brush and vacuum the burn
pot� The burn pot can be easily cleaned inside the stove�
Remove the burn pot and clean the space underneath�
Do not damage the ignition when cleaning with the brush� Vacuum
out the pipe of the ignition�
Note
Clean the fire trough regularly� Only clean when cold, when embers
are extinguished!