Vacuum the combustion residues off the flue gas collecting duct,
especially the area to the convection fan�
Open the rear side panel with the key for the ombustion chamber
door�
Unscrew the two wing nuts and remove the outer cleaning lid�
Vacuum the combustion residues off the flue gas collecting duct,
especially the area to the flue gas fan�
Install the removed parts in reverse order�
Reset the cleaning interval (see
Note
Your stove may suck in false air via incorrectly sealed cleaning
covers; this air may lead to incomplete combustion in the fire
trough and thus piling up of pellets� DANGER of FIRE!
To ensure the proper operation of your pellet stove, replace any
defect (porous, frayed) seals after cleaning and maintenance�
RESET - CLEANING INTERVAL

Cleaning the convection air openings

Vacuum clean any dust deposits from the convection air openings
at regular intervals�
The stove should be cleaned thoroughly prior to the start of the
heating season to prevent excess odour�
Note
To prevent your stove from overheating of the internal components,
do never cover the convection fins!

Combustion air - intake

If necessary, please also clean the air intake with a hoover�
Note
Only when the stove is cold! You could vacuum out embers – FIRE
RISK!
)�