Endress+Hauser Levelflex FMP53 Operating Instructions Manual
Endress+Hauser Levelflex FMP53 Operating Instructions Manual

Endress+Hauser Levelflex FMP53 Operating Instructions Manual

Guided level-radar
Hide thumbs Also See for Levelflex FMP53:
Table of Contents

Advertisement

Quick Links

Operating Instructions
Levelflex FMP53
Guided Level-Radar
Level measurement in liquids and hygienic applications
BA01007F/00/EN/13.12
71206454
Valid as of version
01.00.zz

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Levelflex FMP53

  • Page 1 Operating Instructions Levelflex FMP53 Guided Level-Radar Level measurement in liquids and hygienic applications BA01007F/00/EN/13.12 71206454 Valid as of version 01.00.zz...
  • Page 3: Table Of Contents

    Levelflex FMP53 Table of contents Table of contents 6.2.3 Notes on the mechanical load of the Important document information ..5 probe ......29 About this document .
  • Page 4 Table of contents Levelflex FMP53 14.2 Communication-specific accessories ..78 Commissioning via operating menu 14.3 Service-specific accessories ....79 (On-site display, FieldCare) .
  • Page 5: Important Document Information

    The document types listed are available: • On the CD supplied with the device • In the Download Area of the Endress+Hauser Internet site: www.endress.com ® Download 1.1.3 Safety Instructions (XA) for Levelflex FMP53 Depending on the approval, the following Safety Instructions (XA) are supplied with the instrument.
  • Page 6: Document Conventions

    Important document information Levelflex FMP53 Feature Approval Safety Instructions Safety Instructions HART PROFIBUS FOUNDATION Fieldbus FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia, NI Cl.1 Div.2 XA00531F XA00573F FM XP Cl.I,II,III Div.1 Gr.A-G, AEx d, NI Cl.1 Div.2 XA00532F XA00572F IECEx zone 0 Ex ia IIC T6 Ga...
  • Page 7: Electrical Symbols

    Levelflex FMP53 Important document information 1.2.2 Electrical symbols Symbol Meaning Direct current A terminal to which DC voltage is applied or through which direct current flows. A0011197 Alternating current A terminal to which alternating voltage (sine-wave) is applied or through which alternating current flows.
  • Page 8: Symbols In Graphics

    Important document information Levelflex FMP53 Symbol Meaning Series of steps … Result of a sequence of actions à Help in the event of a problem A0013562 1.2.5 Symbols in graphics Symbol Meaning 1, 2, 3 ... Item numbers Series of steps …...
  • Page 9: Basic Safety Instructions

    The manufacturer is not liable for damage caused by improper or non-designated use. Verification for borderline cases: For special measured materials and cleaning agents, Endress+Hauser is glad to provide ► assistance in verifying the corrosion resistance of wetted materials, but does not accept any warranty or liability.
  • Page 10: Operational Safety

    It fulfills general safety requirements and legal requirements. It also conforms to the EC directives listed in the device-specific EC declaration of conformity. Endress+Hauser confirms this fact by applying the CE mark. Endress+Hauser...
  • Page 11: Product Description

    Levelflex FMP53 Product description Product description Product design 3.1.1 Compact device Levelflex A0013421 Design of the Levelflex å 1 Electronics housing Process connection Rod probe Endress+Hauser...
  • Page 12: Electronics Housing

    Product description Levelflex FMP53 3.1.2 Electronics housing A0012422 Design of the electronics housing å 2 Electronics compartment cover Display module Main electronics module Cable glands (1 or 2, depending on instrument version) Nameplate I/O electronics module Terminals (pluggable spring terminals)
  • Page 13 Levelflex FMP53 Product description US Patents EP Patents 6.140.940 6.481.276 6.512.358 1 301 914 6.559.657 1 020 735 6.640.628 6.691.570 6.847.214 7.441.454 7.477.059 1 389 337 7.965.087 Endress+Hauser...
  • Page 14: Incoming Acceptance And Product

    Incoming acceptance and product identification Levelflex FMP53 Incoming acceptance and product identification Incoming acceptance DELIVERY NOTE 1 = 2 A0013696 A0016870 Is the order code on the delivery note (1) identical to the order code on the product sticker (2)?
  • Page 15: Product Identification

    Are the CD-ROMs (product documentation, operating tool) and documentation present? If required (see nameplate): Are the Safety Instructions (XA) present? If one of the conditions does not comply, contact your Endress+Hauser distributor. Product identification The following options are available for identification of the measuring device: •...
  • Page 16: Nameplate

    Incoming acceptance and product identification Levelflex FMP53 4.2.1 Nameplate 92 (3.62) Order code: Ser. no.: Ext. ord. cd.: LN = MWP: Lref = Mat.: DeviceID: Dev.Rev.: if modification see sep. label Date: mm (in) 19 18 17 16 A0010725 Nameplate of the Levelflex å...
  • Page 17 Levelflex FMP53 Incoming acceptance and product identification Approval: ATEX II 1/3G Ex ic(ia) IIC T6 ATEX II 3G Ex nA IIC T6 ATEX II 3G Ex ic IIC T6 ATEX II 1/3G Ex nA(ia) IIC T6 ATEX II 1/2G Ex ia IIC T6, 1/2D Ex ia IIIC IP6x...
  • Page 18 Incoming acceptance and product identification Levelflex FMP53 Housing: GT19 dual compartment, Plastics PBT GT20 dual compartment, Alu coated Special version, TSP-no. to be sepc. Electrical connection: Gland M20, IP66/68 NEMA4X/6P Thread M20, IP66/68 NEMA4X/6P Thread G1/2, IP66/68 NEMA4X/6P Thread NPT1/2, IP66/68 NEMA4X/6P Plug M12, IP66/68 NEMA4X/6P Plug 7/8", IP66/68 NEMA4X/6P...
  • Page 19 Levelflex FMP53 Incoming acceptance and product identification Process connection: Tri-Clamp ISO2852 DN25-38 (1...1-1/2"), 3A, 316L Varivent pipe DN40-162 PN16, 316L SMS 2" PN25, 316L SMS 1-1/2" PN25, 316L Ingold fitting 25x46 mm, 316L Thread M24, 316L, install > accessory weld-in adapter Special version, TSP-no.
  • Page 20 Incoming acceptance and product identification Levelflex FMP53 Additional Approval: (Multiple options can be selected) CoC-ASME BPE Special version, TSP-no. to be sepc. Probe Design: (Multiple options can be selected) Sensor compact, detachable Sensor remote, 3m/9ft cable, detachable+mounting bracket Sensor remote, 6m/19ft cable, detachable+mounting bracket Special version, TSP-no.
  • Page 21: Storage, Transport

    Levelflex FMP53 Storage, Transport Storage, Transport Storage conditions • Permitted storage temperature: –40 to +80 °C (–40 to +176 °F) • Use the original packaging. Transport product to the measuring point WARNING Risk of injury if the hosuing breaks away! Transport the measuring device to the measuring point in its original packaging or at the ►...
  • Page 22: Mounting

    Mounting Levelflex FMP53 Mounting Mounting dimensions 6.1.1 Dimensions of the electronics housing 78 (3.07) 90 (3.54) A0015133 Housing GT19 (Plastics PBT); Dimensions in mm (in) å 4 90 (3.54) 78 (3.07) A0015134 Housing GT20 (Alu coated); Dimensions in mm (in) å...
  • Page 23: Dimensions Of The Mounting Bracket

    Levelflex FMP53 Mounting 6.1.2 Dimensions of the mounting bracket 122 (4.8) 140 (5.5) 175 (6.9) 158 (6.2) Ø 42 ... 60 mm (inch) (1-1/4 ... 2) A0014793 Mounting bracket for the electronics housing å 6 Wall mounting Pipe mounting For the "Sensor remote" device version (see feature 060 of the product structure), the mounting bracket is part of the delivery.
  • Page 24: Fmp53: Dimensions Of Probe

    Mounting Levelflex FMP53 6.1.3 FMP53: Dimensions of probe ø59.4 (ø2.34) (4.8) ø59.35 (ø2.34) ø59.35 ø53.5 (ø2.34) (ø2.11) SW27 SW27 AF27 AF27 ø25 (ø0.98) ø13 SW10 (ø0.51) AF10 ø53.5 SW10 (ø2.11) ø8 ø53.5 AF10 ø13 (ø0.31) (ø2.11) (ø0.51) SW27 ø25 (ø0.98)
  • Page 25: Fmp53: Dimensions Of Process Connection

    Levelflex FMP53 Mounting 6.1.4 FMP53: Dimensions of process connection Version Dimensions [mm (inch)] M24x1.5 DIN11864-1 A DN25 tube DIN11866-A, 316L ø42.9 (ø1.69) A0012763 M24x1.5 DIN11864-1 A DN50 tube DIN11866-A, 316L ø66.9 (ø2.63) A0012764 M24x1.5 DIN11851 DN50 PN40 cap-nut, 316L ø68 (ø2.68) A0012766 M24x1.5...
  • Page 26 Mounting Levelflex FMP53 Version Dimensions [mm (inch)] ø115 (ø4.53) NEUMO BioControl D80 PN16, 316L M24x1.5 (Not available with Probe Design "Sensor compact", feature 600, option MA) ø87.4 (ø3.44) ø140 (ø5.51) A0012769 M24x1.5 Tri-Clamp ISO2852 DN40-51 (2"), 316L ø63.9 (ø2.52) A0012770 M24x1.5...
  • Page 27: Mounting Requirements

    Levelflex FMP53 Mounting Version Dimensions [mm (inch)] Thread M24, 316L A0014608 For the process connection U1J you need the following weld-in adapter: Order code: 71041381 = 16 bar (232 psi) Material: 316L (1.4435) ø65 (ø A0012776 Mounting requirements 6.2.1 Suitable mounting position...
  • Page 28: Applications With Restricted Mounting

    Mounting Levelflex FMP53 Additional conditions • When mounting in the open, a weather protection cover (1) may be installed to protect the device against extreme weather conditions. • Do not mount the probe in the filling curtain (2). When mounting the electronics housing into a recess (e.g. in a concrete ceiling), observe a minimum distance of 100 mm (4 inch) between the cover of the terminal compartment / electronics compartment and the wall.
  • Page 29: Notes On The Mechanical Load Of The Probe

    Levelflex FMP53 Mounting Divisible probes SW10 AF10 A0014166 If there is little mounting space (distance to the ceiling), it is advisable to use divisible rod probes (Æ 8 mm). • max. probe length 6 m/236 inch • max. sideways capacity 10 Nm •...
  • Page 30: Special Mounting Conditions

    Mounting Levelflex FMP53 LN [m]: Probe length Calculation example Friction factor c 0,9 (on the assumption of a turbulent current - high Reynolds number) Density r [kg/m 1000 (e.g. water) Probe diameter d [m] 0,008 L = L (worst case) A0014175 Bending torque [M] on rod probes, diameter 8mm (1/3”)
  • Page 31 Levelflex FMP53 Mounting Installation close to tank wall By installing the probe close to the tank wall, the cleaning effect is improved in cases where a spray ball is used. The cleaning jet is deflected against the tank wall and onto the probe. This means that those parts of the probe are cleaned which would normally not be reached by the spray ball jet.
  • Page 32 Mounting Levelflex FMP53 To measure, Levelflex with a rod or rope probe needs a metallic surface at the process connection. Therefore: Mount a metal sheet with a diameter of at least 200 mm (8") to the probe at the process connection.
  • Page 33 Levelflex FMP53 Mounting The device looks for the end of probe signal in the subtracted curve. Thus, the value of the measured probe length depends on the mapping. In order to obtain an exact value, it is advisable to determine the probe length manually using the envelope curve display in FieldCare.
  • Page 34 Mounting Levelflex FMP53 A0015809 Hygienic process connections - FMP53 å 7 Tank insulation Compact device Compct device, detachable (feature 600) Sensor remote (feature 600) Endress+Hauser...
  • Page 35: Mounting The Device

    Levelflex FMP53 Mounting Mounting the device 6.3.1 Required mounting tools • To shorten rod or coax probes: Saw • For flanges and other process connections: appropriate mounting tools • To turn the housing: Hexagonal wrench 8 mm 6.3.2 Preparing the device for mounting When shortening the probe: Enter the new length of probe into the Quick Setup which can be found in the electronics housing behind the display module.
  • Page 36: Turning The Transmitter Housing

    Mounting Levelflex FMP53 Mounting the electronics housing 122 (4.8) 140 (5.5) 158 (6.2) 175 (6.9) Ø 42 ... 60 mm (inch) (1-1/4 ... 2) A0014793 Mounting the electronics housing using the mounting bracket å 8 Wall mounting Pipe mounting Connecting the cable Required tools: •...
  • Page 37: Turning The Display Module

    Levelflex FMP53 Mounting max. 350° 8 mm 8 mm A0013713 1. Unscrew the securing screw using an open-ended wrench. 2. Rotate the housing in the desired direction. 3. Firmly tighten the securing screw. (1,5 Nm for plastics housing; 2,5 Nm for aluminium or stainless steel housing).
  • Page 38: Post-Installation Check

    Mounting Levelflex FMP53 Post-installation check Is the device undamaged (visual inspection)? Does the device conform to the measuring point specifications? For example: • Process temperature • Process pressure (refer to the chapter on "Material load curves" of the "Technical Information"...
  • Page 39: Electrical Connection

    Levelflex FMP53 Electrical connection Electrical connection Connection options 7.1.1 PROFIBUS PA / FOUNDATION Fieldbus A0011341 Terminal assignment PROFIBUS PA / FOUNDATION Fieldbus å 9 Without integrated overvoltage protection With integrated overvoltage protection Cable screen: Observe cable specifications (® ä 40)
  • Page 40: Connection Examples For The Switch Output

    Electrical connection Levelflex FMP53 7.1.2 Connection examples for the switch output For HART devices, the switch output is available as an option. See product structure, feature 20: "Power Supply, Output", option B: "2-wire; 4-20mA HART, switch output" Devices with PROFIBUS PA and FOUNDATION Fieldbus always have a switch output.
  • Page 41: Overvoltage Protection

    < 1.5 pF Nominal arrest impulse voltage (8/20 ms) 10 kA External overvoltage protection HAW562 or HAW569 from Endress+Hauser are suited as external overvoltage protection. For detailed information please refer to the following documents: • HAW562: TI01012K • HAW569: TI01013K Connection data 7.3.1...
  • Page 42: Connecting The Measuring Device

    Electrical connection Levelflex FMP53 Connecting the measuring device WARNING Explosion hazard! Comply with the relevant national standards. ► Observe the specifications in the Safety Instructions (XA). ► Only use the specified cable glands. ► Check whether the supply voltage matches the specifications on the nameplate.
  • Page 43 Levelflex FMP53 Electrical connection Connect the cable in accordance with the terminal assignment (® ä 39). 8. When using screened cable: Connect the cable screen to the ground terminal. 9. Screw the cover onto the connection compartment. 10. For instruments with safety pin for the lid: Adjust the safety pin so that its edge is over the edge of the display lid.
  • Page 44: Post-Connection Check

    Electrical connection Levelflex FMP53 Post-connection check Are cables or the device undamaged (visual inspection)? Do the cables comply with the requirements? Do the cables have adequate strain relief? Are all cable glands installed, firmly tightened and correctly sealed? Does the supply voltage match the specifications on the transmitter nameplate? Is the terminal assignment correct (®...
  • Page 45: Operating Options

    å 12 Display module SD02, push buttons; cover must be open for operation Operating options via CDI interface (= Endress+Hauser Common Data Interface) 2.1 Computer with operating tool (FieldCare) 2.2 Commubox FXA291, connected to the CDI interface of the device 8.1.2...
  • Page 46 Operating options Levelflex FMP53 PROFIBUS DP ENDRESS + HAUSER PROFIBUS PA Prosonic Micropilot Levelflex A0011275 The complete measuring system consists of devices and: å 14 Segment coupler Computer with Profiboard/Proficard and operating tool (FieldCare) PLC (programmable logic controller) More functions (valves etc.)
  • Page 47: The Operating Menu

    Levelflex FMP53 Operating options The operating menu 8.2.1 Structure Language Display/operation Parameter 1 Parameter 2 Parameter N Setup Setup parameter 1 Setup parameter 2 Setup parameter N Enter access code Advanced setup Parameter 1 Parameter N Submenu 1 Submenu N...
  • Page 48: Submenus And User Roles

    Operating options Levelflex FMP53 8.2.2 Submenus and user roles The submenus are designed for different user roles. A user role is defined by typical tasks within the lifecycle of the device. User role Typical tasks Submenu Content/Meaning Operator Tasks in the ongoing process: "Language"...
  • Page 49 Levelflex FMP53 Operating options WP SIM DISPL Spare part: FMP52X-AB 02.01.03 Dev_R ex works SW update #1 SW update #2 A0013132 1. Unscrew the lid from the compartment for the display and operating module. 2. Slightly turn the display and operating module to remove it from the compartment.
  • Page 50: Display And Operating Module

    Operating options Levelflex FMP53 Display and operating module 8.3.1 Display appearance User ABC_ DEFG HIJK LMNO PQRS TUVW A0012635 Appearance of the display and operation module for on-site operation å 16 Measured value display (1 value max. size) 1.1 Header containing tag and error symbol (if an error is active) 1.2 Measured value symbols...
  • Page 51 Levelflex FMP53 Operating options Display symbols for the submenus Symbol Meaning Display/operation Is displayed: • in the main menu next to the selection "Display/operation" A0011975 • in the header, if you are in the "Display/operation" menu Setup Is displayed: • in the main menu next to the selection "Setup"...
  • Page 52 Operating options Levelflex FMP53 Measured value symbols Symbol Meaning Measured values Level A0011995 Distance A0011996 Current output A0011998 Measured current A0011999 Terminal voltage A0012106 Temperature of the electronics or the sensor A0012104 Measuring channels Measuring channel 1 A0012000 Measuring channel 2...
  • Page 53: Operating Elements

    Levelflex FMP53 Operating options 8.3.2 Operating elements Meaning Minus key For menu, submenu Moves the selection bar upwards in a picklist. A0013969 For text and numeric editor In the input mask, moves the selection bar to the left (backwards). Plus key For menu, submenu Moves the selection bar downwards in a picklist.
  • Page 54: Entering Numbers And Text

    Operating options Levelflex FMP53 8.3.3 Entering numbers and text Numeric editor Text editor A0013941 A0013999 Editing view Display area of the entered values Input mask Operating elements Input mask The following input symbols are available in the input mask of the numeric and text editor:...
  • Page 55 Levelflex FMP53 Operating options Confirms selection. A0013985 Switches to the selection of the correction tools. A0013987 Exits the input without applying the changes. A0013986 Clears all entered characters. A0014040 Operating symbols in the numeric editor A0016621 A0013985 A0013986 Confirms selection.
  • Page 56: Envelope Curve On The Display And Operating Module

    Operating options Levelflex FMP53 8.3.4 Envelope curve on the display and operating module In order to assess the measuring signal, the envelope curve and - if a mapping has been recorded - the mapping curve can be displayed: (2s) A0014277...
  • Page 57: Integration Into A Profibus

    Levelflex FMP53 Integration into a PROFIBUS network Integration into a PROFIBUS network Overview of the device database files (GSD) Manufacturer ID 17 (0x11) Ident number 0x1558 Profile version 3.02 GSD file Information and files under: • www.endress.com GSD file version •...
  • Page 58 Integration into a PROFIBUS network Levelflex FMP53 A0015903 Example of software addressing; switch 8 is in position "ON"; the address is defined in the operating menu å 19 (Setup ® Device address) Endress+Hauser...
  • Page 59: Commissioning Via Operating Menu (On-Site Display, Fieldcare)

    Levelflex FMP53 Commissioning via operating menu (On-site display, FieldCare) Commissioning via operating menu (On-site display, FieldCare) 10.1 Installation and function check Make sure that all final checks have been completed before you start up your measuring point: • Checklist "Post-installation check" (® ä 38) •...
  • Page 60: Setting The Operating Language

    Commissioning via operating menu (On-site display, FieldCare) Levelflex FMP53 10.4 Setting the operating language 10.4.1 Setting the operating language via the display module A0013637 10.4.2 Setting the language via operating tool (FieldCare) A0015305-EN Endress+Hauser...
  • Page 61: Configuration Of A Level Measurement

    "Tank type" = "Bypass/pipe" If required, lower DCs can ben entered into "Setup ® Advanced Setup ® Level ® Medium property". However, for DC<1.6 the measuring range may be reduced; for details please contact Endress+Hauser. Endress+Hauser...
  • Page 62: Configuration Of The On-Site Display

    Commissioning via operating menu (On-site display, FieldCare) Levelflex FMP53 10.6 Configuration of the on-site display 10.6.1 Factory settings of the on-site display for level measurements Parameter Factory setting for devices with 1 current Factory setting for devices with 2 current...
  • Page 63: Trouble Shooting

    Levelflex FMP53 Trouble shooting Trouble shooting 11.1 Trouble-shooting instructions Generel errors Error Possible cause Remedial action Device does not respond. Supply voltage does not match the value Connect the correct voltage. indicated on the nameplate. The polarity of the supply voltage is Correct the polarity.
  • Page 64: Diagnostic Information On Local Display

    Trouble shooting Levelflex FMP53 Error Possible cause Remedial action Interference echo Carry out mapping over entire probe when the tank is empty (® ä 97). Wrong slope of the level in the Wrong tank type selected. Set the Tank type parameter correctly entire measuring range (®...
  • Page 65: Calling Up Remedial Measures

    Levelflex FMP53 Trouble shooting Diagnostics event and event text The fault can be identified using the diagnostics event. The event text helps you by providing information about the fault. In addition, the corresponding symbol is displayed before the diagnostics event.
  • Page 66: Diagnostic Event In The Operating Tool

    Trouble shooting Levelflex FMP53 Ã The message for the remedial measures for the diagnostic event opens. 2. Press S + O simultaneously. Ã The message about the remedial measures closes. 11.3 Diagnostic event in the operating tool If a diagnostic event is present in the operating tool, the status signal appears in the top left status area along with the corresponding symbol for event level in accordance with NAMUR NE 107: •...
  • Page 67: Overview Of Diagnostic Events

    Levelflex FMP53 Trouble shooting / ../Diagnose list Diagnostics F273 Main electronic Diagnostics 2 Diagnostics 3 A0014006-EN Calling up and closing the remedial measures 1. Press F. Ã The message for the remedial measures for the selected diagnostic event opens. 2. Press S + O simultaneously.
  • Page 68: Configuration Failures

    Trouble shooting Levelflex FMP53 Diagnostic event Maintenance instructions Error behavior Code Description F271 Main electronic failure 1. Restart device. Alarm 2. Change main electronic module. F272 Main electronic failure 1. Restart device. Alarm M272 2. Contact service. F273 Main electronic failure 1.
  • Page 69: Event Logbook

    Levelflex FMP53 Trouble shooting Diagnostic event Maintenance Error behavior instructions Code Description F825 Operating temperature 1. Check ambient Alarm S825 temprature. Warning 2. Check process temperature. S921 Change of reference 1. Check reference Warning configuration. 2. Check pressure. 3. Check sensor.
  • Page 70: Filtering The Event Logbook

    Trouble shooting Levelflex FMP53 In addition to the operation time of its occurrence, each event is also assigned a symbol that indicates whether the event has occurred or is ended: • Diagnostic event – : Event has occurred – : Event has ended •...
  • Page 71: Software History

    Levelflex FMP53 Trouble shooting Information Event text event I1186 Device with display restored I1187 Measuring point copied via display I1188 Display data cleared I1189 Device backup compared I1264 Safety sequence aborted I1335 Firmware changed 11.7 Software history Date Software Modifications...
  • Page 72: Repairs

    12.1.1 Repair concept The Endress+Hauser repair concept assumes that the devices have a modular design and that repairs can be done by the Endress+Hauser service or specially trained customers. Spare parts are contained in suitable kits. They contain the related replacement instructions.
  • Page 73: Spare Parts

    Levelflex FMP53 Repairs 12.2 Spare parts • A few interchangeable measuring device components are identified by a spare part nameplate. This contains information about the spare part. • The connection compartment cover of the device contains a spare part nameplate that includes the following information: –...
  • Page 74: Maintenance

    Maintenance Levelflex FMP53 Maintenance The measuring device requires no special maintenance. 13.1 Exterior cleaning When exterior-cleaning the device, always use cleaning agents that do not attack the surface of the hosuing and the seals. 13.2 Cleaning the probe 13.2.1 Cleaning the probe in the tank If the device has been mounted in a suitable position, the probe can be cleaned in the tank using a spray ball (®...
  • Page 75: Cleaning The Probe Outside The Tank

    Levelflex FMP53 Maintenance 13.2.2 Cleaning the probe outside the tank The probe can be disassembled so it can be cleaned better. The disassembly requires the following tools: • vise with fiber braces (surface protection for the polished probe rod) • hook wrench Æ 54 mm (21 in) •...
  • Page 76: Accessories

    Accessories Levelflex FMP53 Accessories 14.1 Device-specific accessories Accessory Description Weather protection cover mm (in) A0015466 298.5 (11.8) 273.8 (10.8) 164 (6.46) 255.1 (10) mm (in) A0015472 37.8 mm (1.49 in) 54 mm (2.13 in) The weather protection cover can be ordered together with the device (product structure, feature 620 "Accessory Enclosed", option PB "Weather Protection...
  • Page 77 Levelflex FMP53 Accessories Accessory Description Mounting bracket for the electronics housing 122 (4.8) 140 (5.5) 175 (6.9) 158 (6.2) Ø 42 ... 60 mm (inch) (1-1/4 ... 2) A0014793 Wall mounting Pipe mounting For the "Sensor remote" device version (see feature 060 of the product structure), the mounting bracket is part of the delivery.
  • Page 78: Communication-Specific Accessories

    For details refer to the document SD01007F. 14.2 Communication-specific accessories Accessory Description Commubox FXA291 Connects Endress+Hauser field devices with CDI interface (= Endress+Hauser Common Data Interface) to the USB interface of a computer. For details refer to Technical Information TI405C/07 Endress+Hauser...
  • Page 79: Service-Specific Accessories

    Accessory Description FieldCare Endress+Hauser's FDT-based Plant Asset Management tool. Helps to configure and maintain all field devices of your plant. By supplying status information it also supports the diagnosis of the devices. For details refer to Operating Instructions BA027S/04 and BA059S/04 14.4...
  • Page 80: Return

    +Hauser, as an ISO-certified company, is required to follow certain procedures when handling returned products that are in contact with medium. To ensure swift, safe and professional device returns, please read the return procedures and conditions on the Endress+Hauser website at www.services.endress.com/return-material Endress+Hauser...
  • Page 81: Disposal

    Levelflex FMP53 Disposal Disposal In case of disposal please separate the different components according to their material consistence. Endress+Hauser...
  • Page 82: Overview Of The Operating Menu

    Overview of the operating menu Levelflex FMP53 Overview of the operating menu Language (® ä 88) Display/operation ® Access status display (® ä 89) Locking status (® ä 89) Format display (® ä 89) Contrast display (® ä 91) Display interval (®...
  • Page 83 Levelflex FMP53 Overview of the operating menu Setup ® Advanced setup ® Linearization ® Linearization type (® ä 105) Unit linearized (® ä 105) Free text (® ä 106) Maximum value (® ä 106) Diameter (® ä 107) Intermediate height (®...
  • Page 84 Overview of the operating menu Levelflex FMP53 Out value (® ä 120) Out status (® ä 120) Out status HEX (® ä 121) Setup ® Advanced setup ® Digital input 1...4 ® Channel (® ä 122) Invert (® ä 122) Fail safe type (®...
  • Page 85 Levelflex FMP53 Overview of the operating menu Display interval (® ä 92) Display damping (® ä 132) Header (® ä 133) Header text (® ä 133) Separator (® ä 134) Number format (® ä 134) Decimal places menu (® ä 134) Setup ®...
  • Page 86 Overview of the operating menu Levelflex FMP53 Diagnostics ® Measured value ® Distance (® ä 95) Level linearized (® ä 144) Switch status (® ä 118) Diagnostics ® Measured value ® Analog input 1...6 ® Channel (® ä 119) Out value (®...
  • Page 87 Levelflex FMP53 Overview of the operating menu Diagnostics ® Device check ® Start device check (® ä 151) Result device check (® ä 151) Last check time (® ä 151) Level signal (® ä 151) Launch signal (® ä 152) Diagnostics ®...
  • Page 88: Description Of Device Parameters

    Description of device parameters (operating menu) Levelflex FMP53 Description of device parameters (operating menu) • : Marks the navigation path to the parameter via the display and operating module. • : Marks the navigation path to the parameter via an operating tool (e.g. FieldCare).
  • Page 89: Display/Operation" Menu

    Levelflex FMP53 Description of device parameters (operating menu) 18.1 "Display/operation" menu This menu only appears if the device has a local display. Access status display Display/operation ® Access stat. disp. Navigation Setup ® Advanced setup ® Access stat. disp. Description Use this function to view the access authorization to parameters via onsite operation.
  • Page 90 Description of device parameters (operating menu) Levelflex FMP53 Navigation Display/operation ® Format display Setup ® Advanced Setup ® Display ® Format display Description Use this function to select how the measured value is shown on the local display. The display format (size, bar graph etc.) and number of measured values displayed simultaneously (1 to 4) can...
  • Page 91 Levelflex FMP53 Description of device parameters (operating menu) Additional information 1 value, max. size A0011948-EN 1 bargraph + 1 value A0012011-EN 2 values A0012013-EN 1 value large + 2 values A0012016-EN 4 values A0012019-EN Contrast display Display/operation ® Contrast display...
  • Page 92: Setup" Menu

    Description of device parameters (operating menu) Levelflex FMP53 Factory setting 30 % Display interval Navigation Display/operation ® Display interval Setup ® Advanced Setup ® Display ® Display interval Description Use this function to set the length of time the measured values are displayed if the values alternate on the display.
  • Page 93 Levelflex FMP53 Description of device parameters (operating menu) Selection • Metallic • Bypass/pipe • Non metallic • Mounted outside Depending on the probe there may be further options. Factory setting Depending on the type of probe. Tube diameter Setup ® Tube diameter...
  • Page 94 Description of device parameters (operating menu) Levelflex FMP53 Description Defines the empty calibration E. E is the distance between the reference point (lower edge of the flange or threaded connection) and the minimum level (0%). A0013178 Input range Depending on the selected distance unit and the probe.
  • Page 95 Levelflex FMP53 Description of device parameters (operating menu) Description Displays the measured level L (before linearization) A0013194 Additional information The value is displayed in the selected "Level unit" (® ä 103). Distance Setup ® Distance Navigation Diagnostics ® Measured val. ® Distance...
  • Page 96 Description of device parameters (operating menu) Levelflex FMP53 Display options • Strong The evaluated echo exceeds the threshold by at least 10 mV • Medium The evaluated echo exceeds the threshold by at least 5 mV. • Weak The evaluated echo exceeds the threshold by less than 5 mV.
  • Page 97: Mapping" Sequence

    Levelflex FMP53 Description of device parameters (operating menu) 18.2.1 "Mapping" sequence Confirm distance Setup ® Mapping ® Confirm distance Navigation Description Confirmation whether the measured distance matches the actual distance. Depending on the selection, the device automatically determines the range over which the mapping will be recorded.
  • Page 98: Advanced Setup" Submenu

    Description of device parameters (operating menu) Levelflex FMP53 Description Definition of the distance up to which the mapping curve will be recorded. Input range 0.1 m (0.33 ft) to length of probe (LN) Factory setting 0.1 m (0.33 ft) Additional information The distance is measured from the reference point, i.e.
  • Page 99 If no key is pressed for 10 minutes, or the user goes from the navigation and editing mode back to the measured value display mode, the device automatically locks the write-protected parameters after another 60 s . Please contact your Endress+Hauser Sales Center if you lose your access code Input range 0 to 9 999 Define access code Setup ®...
  • Page 100 Description of device parameters (operating menu) Levelflex FMP53 Description Use this function to enter a unique name for the measuring point so it can be identified quickly within the plant. The name is displayed in the header: XXXXXXXXX A0013375 Header text Input range Max.
  • Page 101 Factory setting Unknown Additonal information Dielectric constants of important media commonly used in the industry are summarized in the document SD106F, which can be downloaded from the Endress+Hauser web page (www.endress.com). Process property Navigation Setup ® Advanced Setup ® Level ® Process property...
  • Page 102 Description of device parameters (operating menu) Levelflex FMP53 Options For "Medium type" = "Liquid" • Fast > 1 m(40")/min • Standard < 1 m(40")/min • Medium < 10 cm(4")/min • Slow < 1 cm(0.4")/min • No filter For "Medium type" = "Solid"...
  • Page 103 Levelflex FMP53 Description of device parameters (operating menu) Additional information For two-phase media the "Emulsion layer" option ensures that always the total level is detected (Example: Oil/condensate application). The "Probe near bottom" option helps to improve the empty detection, especially if the probe is mounted close to the tank bottom.
  • Page 104 Description of device parameters (operating menu) Levelflex FMP53 Additional information No echos are evaluated within the blocking distance UB. Therefore, UB can be used to suppress interference echos within the upper end of the probe. A0013219 Level correction Setup ® Advanced setup ® Level ® Level correction...
  • Page 105 Levelflex FMP53 Description of device parameters (operating menu) The "Linearization" submenu Linearization type Navigation Setup ® Advanced setup ® Linearization ® Linearization type Description Defines the type of linearization Selection • None The level is transmitted to the output without 100% linearization.
  • Page 106 Description of device parameters (operating menu) Levelflex FMP53 Description Defines the unit of the linearized value. Selection • Free text • t • lb • ton • kg • impGal • UsGal • cf • cm • dm • m •...
  • Page 107 Levelflex FMP53 Description of device parameters (operating menu) Factory setting Diameter Navigation Setup ® Advanced setup ® Linearization ® Diameter Condition Only visible if one of the following linearization types has been selected: • Horizontal cylinder • Sphere Description Definition of the tank diameter Input range 0 ...
  • Page 108 Description of device parameters (operating menu) Levelflex FMP53 Navigation Setup ® Advanced setup ® Linearization ® Table mode Condition Only visible if the "Table" linearization type has been selected. Description Defines the method used to enter linearization points into the table.
  • Page 109 Levelflex FMP53 Description of device parameters (operating menu) Additional information For Table mode = Manual: Level is a writable parameter. For Table mode = Semi-automatic: Level is a read-only parameter. Customer value Setup ® Advanced setup ® Linearization ® Customer value...
  • Page 110 Description of device parameters (operating menu) Levelflex FMP53 The "Safety settings" submenu Output echo lost Navigation Setup ® Advanced setup ® Safety settings ® Output echo lost Description Defines the output signal in the case of a lost echo. Selection •...
  • Page 111 Levelflex FMP53 Description of device parameters (operating menu) Description Defines the slope of the ramp in the case of a lost echo. 100% A0013269 Delay echo lost Ramp echo lost (positive value) Ramp echo lost (negative value) Input range -9999999,0 to + 9999999,0 %/min...
  • Page 112 Description of device parameters (operating menu) Levelflex FMP53 The "WHG confirmation" sequence The "WHG confirmation" sequence is only available for devices with SIL approval (feature 590: "Additional Approval", option LC: "WHG overfill prevention") which are currently not in the WHG-locked state.
  • Page 113 Levelflex FMP53 Description of device parameters (operating menu) The "Probe length correction" sequence The Probe length correction sequence helps to ensure that the end of probe signal within the envelope curve is correctly assigned by the evaluation algorithm. The assignment is correct if the length of probe indicated by the device matches the acutal lenght of the probe.
  • Page 114 Description of device parameters (operating menu) Levelflex FMP53 Present length Setup ® Advanced setup ® Probe length corr. ® Pres. length Navigation Description Depending on the parametrization: • In most cases: Displays the measured length of probe (according to the detected end of probe signal).
  • Page 115 Levelflex FMP53 Description of device parameters (operating menu) Description Allocates a DI block to the switch output. Options • Off No digital block is allocated. • Digital output 1 • Digital output 2 • Digital output 3 • Digital output 4...
  • Page 116 Description of device parameters (operating menu) Levelflex FMP53 Navigation Setup ® Advanced setup ® Switch output ® Switch-on value / Switch-off value Only visible for Switch output function = Limit and Assign limit ¹ Off. Prerequisite Description Define the switch-on point and switch-off point for the limit evaluation.
  • Page 117 Levelflex FMP53 Description of device parameters (operating menu) Additional information The switching behavior depends on the relative position of the two switch points. Switch-on point > Switch-off point: The output is closed if the measured value exceeds the switch-on point.
  • Page 118 Description of device parameters (operating menu) Levelflex FMP53 Prerequisite Only visible for Switch output function = Limit and Assign limit ¹ Off. Description Defines the delay for the switching on of the output. Range of values 0 to 100 s...
  • Page 119 Levelflex FMP53 Description of device parameters (operating menu) Invert output signal Setup ® Advanced setup ® Switch output ® Invert output signal Navigation Description Allows to invert the behavior of the switch output. Options • No The behavior of the switch output is as described above.
  • Page 120 Description of device parameters (operating menu) Levelflex FMP53 Fail safe type Setup ® Advanced setup ® Analog input 1...6 ® Fail safe type Navigation Description Defines the output value of the AI block in case of an error. Options • Fail safe value The output value in case of an error is defined in the Fail safe value parameter.
  • Page 121 Levelflex FMP53 Description of device parameters (operating menu) Display options • Good • Uncertain • Bad Additional information For the meaning of the status refer to BA00034S, "PROFIBUS DP/PA - Guidelines for planning and commissioning" Out status HEX Setup ® Advanced setup ® Analog input 1...6 ® Out status HEX Navigation Diagnostics ®...
  • Page 122 Description of device parameters (operating menu) Levelflex FMP53 "Digital input 1" ... "Digital input 4" submenus The Digital input 1 to Digital input 4 submenus are used to configure the DI blocks of the device. Channel Setup ® Advanced setup ® Digital input 1...4 ® Channel Navigation Diagnostics ®...
  • Page 123 Levelflex FMP53 Description of device parameters (operating menu) Factory setting Fail safe value Setup ® Advanced setup ® Digital input 1...4 ® Fail safe value Navigation Prerequisite Only visible for Fail safe type = Fail safe value. Description Defines the output value of the DI block in case of an error.
  • Page 124 Description of device parameters (operating menu) Levelflex FMP53 Additional information The hexadecimal code give more detailed information on the device state than the Out status parameter. For the meaning of the hexadecimal code refer to BA00034S, "PROFIBUS DP/PA - Guidelines for planning and commissioning".
  • Page 125 Levelflex FMP53 Description of device parameters (operating menu) Fail safe type Setup ® Advanced setup ® Analog output 1...4 ® Fail safe type Navigation Description Defines the output behavior of the AO block in the case of an error. Options •...
  • Page 126 Description of device parameters (operating menu) Levelflex FMP53 Display options • Good • Uncertain • Bad Out status HEX Setup ® Advanced setup ® Analog output 1...4 ® Out status HEX Navigation Diagnostics ® Measured value ® Analog output 1...4 ® Out status HEX Description Displays the hexadecimal status of the output value of the block.
  • Page 127 Levelflex FMP53 Description of device parameters (operating menu) Setup ® Advanced setup ® Digital output 1...4 ® Invert Navigation Description Allows to invert the digital output signal (i.e. to swap the states "0" and "1"). Option • Off • On...
  • Page 128 Description of device parameters (operating menu) Levelflex FMP53 Factory setting Out value Navigation Setup ® Advanced setup ® Digital output 1...4 ® Out value Diagnose ® Measured value ® Digital output 1...4 ® Out value Description Displays the current output value of the block.
  • Page 129 Levelflex FMP53 Description of device parameters (operating menu) The "Display" submenu For operating tools: The Display submenu is only visible if a display module is connected to the device. Format display (® ä 89) Value 1 display Setup ® Advanced setup ® Display ® Value 1 display...
  • Page 130 Description of device parameters (operating menu) Levelflex FMP53 Value 2 display Setup ® Advanced setup ® Display ® Value 2 display Navigation Description Use this function to select one of the measured values to be shown on the local display. If several measured values are displayed at once, the measured value selected here will be the second value to be displayed.
  • Page 131 Levelflex FMP53 Description of device parameters (operating menu) Description Use this function to select one of the measured values to be shown on the local display. If more than two measured values are displayed at once, the measured value selected here will be the third value to be displayed.
  • Page 132 Description of device parameters (operating menu) Levelflex FMP53 Options • None • Level linearized • Distance • Current output 1 • Current output 2 • Measured current • Terminal voltage • Electronics temperature Factory setting For level measurements and 1 current output...
  • Page 133 Levelflex FMP53 Description of device parameters (operating menu) Header Setup ® Advanced setup ® Display ® Header Navigation Description Use this function to select the contents of the header of the local display. The header text only appears during normal operation.
  • Page 134 Description of device parameters (operating menu) Levelflex FMP53 Additional information User entry The number of characters displayed depends on the characters used. Separator Setup ® Advanced setup ® Display ® Separator Navigation Description Use this function to select the decimal separator.
  • Page 135 Levelflex FMP53 Description of device parameters (operating menu) The "Configuration backup display" submenu The Configuration backup display submenu is only visible if a display module is connected to the device. The configuration of the device can be saved to the display module at a certain point of time (backup).
  • Page 136 Description of device parameters (operating menu) Levelflex FMP53 Options • Cancel No action is executed and the user exits the parameter. • Execute backup A backup copy of the current device configuration in the HistoROM (built-in in the device) is saved to the display module of the device.
  • Page 137: The "Diagnostics" Menu

    Levelflex FMP53 Description of device parameters (operating menu) 18.3 The "Diagnostics" menu Actual diagnostics Diagnostics ® Actual diagnos. Navigation Description Use this function to display the current diagnostics message. If two or more messages occur simultaneously, the message with the highest priority is shown on the display.
  • Page 138 Description of device parameters (operating menu) Levelflex FMP53 Operating time (® ä 135) Endress+Hauser...
  • Page 139: Diagnsotics List" Submenu

    Levelflex FMP53 Description of device parameters (operating menu) 18.3.1 "Diagnsotics list" submenu Up to 5 diagnostics messages currently pending are displayed in this submenu. If more than 5 messages are pending, the messages with the highest priority are shown on the display.
  • Page 140: The "Event Logbook" Submenu

    Description of device parameters (operating menu) Levelflex FMP53 18.3.2 The "Event logbook" submenu Filter options Diagnostics ® Event logbook ® Filter options Navigation Description Use this function to select the category (status signal) whose event messages are displayed in the events list.
  • Page 141 Levelflex FMP53 Description of device parameters (operating menu) Additional information User interface Example 1 for display format: I 1091 24d12h13m00s Configuration modified Example 2 for display format: S441 01d4h12min30s Current output 1 HistoROM A HistoROM is a "non-volatile" device memory in the form of an EEPROM.
  • Page 142: Device Information" Submenu

    Use this function to view the serial number of the device. It can also be found on the nameplate. Uses of the serial number • To identify the device quickly, e.g. when contacting Endress+Hauser. • To obtain specific information on the device using the Device Viewer: www.endress.com/deviceviewer...
  • Page 143 Uses of the order code • To order an identical spare device. • To identify the device quickly and easily, e.g. when contacting Endress+Hauser. Display Max. 20-digit character string comprising letters, numbers, punctuation marks or +, - Extended order code 1-3 Diagnostics ®...
  • Page 144: Measured Value" Submenu

    Description of device parameters (operating menu) Levelflex FMP53 18.3.4 "Measured value" submenu Distance (® ä 95) Level linearized Diagnostics ® Measured val. ® Level linearized Navigation Description Displays the linearized level. Switch status (® ä 118) "Analog input 1" ... "Analog input 6" submenu Channel (®...
  • Page 145 Levelflex FMP53 Description of device parameters (operating menu) "Analog output 1" ... "Analog output 4" submenu Out value (® ä 125) Out status (® ä 125) Out status HEX (® ä 126) "Digital output 1" ... "Digital output 4" submenu Out value (®...
  • Page 146: Data Logging" Submenu

    Description of device parameters (operating menu) Levelflex FMP53 18.3.5 "Data logging" submenu Assign channel 1-4 Diagnostics ® Data logging ® Assign channel 1 Navigation Diagnostics ® Data logging ® Assign channel 2 Diagnostics ® Data logging ® Assign channel 3 Diagnostics ®...
  • Page 147 Levelflex FMP53 Description of device parameters (operating menu) Description Definition of the logging interval t for data logging. This defines the interval between the individual data points in the data log, and thus the maximum loggable process time T = 1000 × t •...
  • Page 148 Description of device parameters (operating menu) Levelflex FMP53 Description Use this function to view the measured value trend for the logging channel in the form of a chart. A0013859 • x-axis: depending on the number of channels selected displays 250 to 1000 measured values of a process variable.
  • Page 149: Simulation" Submenu

    Levelflex FMP53 Description of device parameters (operating menu) 18.3.6 "Simulation" submenu Assignment of measured variable Diagnostics ® Simulation ® Assign. meas. var. Navigation Description Use this function to select a process variable for the simulation process that is activated. The display alternates between the measured value and a diagnostics message of the "function check"...
  • Page 150 Description of device parameters (operating menu) Levelflex FMP53 Switch status Diagnostics ® Simulation ® Switch status Navigation Prerequisite Only visible for Switch output simulation = On. Description Use this parameter to define the switch status for the simulation. Options • Open •...
  • Page 151: The "Device Check" Submenu

    Levelflex FMP53 Description of device parameters (operating menu) 18.3.7 The "Device check" submenu Start device check Diagnostics ® Device check ® Start device check Navigation Description Start of a device check. Selection • No No device check is performed. • Yes A device check is performed.
  • Page 152 Description of device parameters (operating menu) Levelflex FMP53 Navigation Diagnostics ® Device check ® Level signal Conditions Only visible if a device check has been performed. Description Displays the result of the device check for the level signal. Display • Check not done •...
  • Page 153: Device Reset" Submenu

    Levelflex FMP53 Description of device parameters (operating menu) 18.3.8 "Device reset" submenu Device reset Diagnostics ® Device reset ® Device reset Navigation Description Use this function to reset the device configuration - either entirely or in part - to a defined state.
  • Page 154: Index

    Index Levelflex FMP53 Index Device address (Parameter) ..... . 96 Device check (Submenu) ..... . 151 Access status display (Parameter) .
  • Page 155 Levelflex FMP53 Index Process induced failures ..... . 68 see In alarm condition Event history ....... . 69 Locking status (Parameter) .
  • Page 156 Index Levelflex FMP53 Table number (Parameter) ..... . 108 Tank type (Parameter) ......92 Ramp echo lost (Parameter) .
  • Page 157 Erklärung zur Kontamination und Reinigung Please reference the Return Authorization Number (RA#), obtained from Endress+Hauser, on all paperwork and mark the RA# clearly on the outside of the box. If this procedure is not followed, it may result in the refusal of the package at our facility.
  • Page 158 www.endress.com/worldwide *71206454* BA01007F/00/EN/13.12 71206454 CCS/COSIMA 71206454...

Table of Contents