#212 (Motor Disabled): The motor disabled advisory will identify that electric
motor operation was stopped by the controller. A fault should have been
generated that will provide additional information as to cause of the issue.
#213 (Disengage Traction): This advisory notifies the operator that the bail
lever is engaged and needs to be released before operation can be continued.
The disengage traction advisory will be displayed if the machine is turned on
with the traction lever already engaged.
#214 (Battery Temperature Too Low): This advisory notifies that the battery
operating temperature is too low and the controller was denied the motor
operation.
#215 (Battery Temperature Too High): This advisory notifies that the battery
operating temperature is too high and the controller was denied the motor
operation.
#216 (Battery Voltage Too High): This advisory notifies that the battery
operating voltage is too high and the controller was denied the motor operation.
#217 (Battery Draw Too High): This advisory notifies an over current situation
and the controller was denied the motor operation.
#218 (Backlap Enabled): This advisory notifies the operator when the backlap
is enabled.
#219 (Backlap Denied, Fault Active): This advisory notifies there is an active
fault on the machine that won't allow the backlap.
#220 (Backlap Confirm Gearbox Neutral): An icon appears on the InfoCenter
to inform the operator to move the gear box lever to Neutral position. Operator
must confirm by clicking the right button on the InfoCenter.