Water Connections - Trane CLCF Climate Changer Manual

Air handling units
Table of Contents

Advertisement

Water connections

Figure 13 – Water coil connections
Sound power levels
Discharge
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan
Unit
speed
1
FWD 08
2
3
1
FWD 10
2
3
1
FWD 12
2
3
1
FWD 14
2
3
1
FWD 20
A = Airflow
2
1 = Connections
3
2 = Gate valve
3 = Discharge gate valve
Intake
4 = Automatic air vent valve
5 = Automatic 3-way actuated valve
Measurement conditions:
6 = Flexible joints
Measurements taken at the horizontal air intake.
Referring to Figures 14-17, it is important to note that:
1.
The cooling coil sections and the evaporative (or honeycomb) humidifier sections without recirculating pump
Fan
are equipped with a condensate drain pipe. (Item 1, Figure 14 (A, B)).
Unit
speed
1
2.
For evaporative humidifier sections equipped with are circulation pump, the drain pipe (used typically for
FWD 08
2
cleaning purposes, item 3, Figure 16 (A, B) needs to be connected to a shut off valve without siphon. There is
3
also an additional overflow pipe which needs to be connected to a siphon. (Item 1,Figure 15 (A, B)).
1
FWD 10
2
Figure 14 A indicates the siphon height for coil section located on negative pressure side.
3
Figure 14 B indicates the siphon height for coil section located on positive pressure side.
1
FWD 12
2
Figure 15 A indicates the siphon height for evaporative humidifier section located on negative pressure side.
3
1
Figure 15 B indicates the siphon height for evaporative humidifier section located on positive pressure side.
FWD 14
2
Figure 16 indicates the fresh water inlet for wasted water type or steam type humidifier sections. The freshwater
3
1
flow control in the section is ensured with a solenoid valve. It is recommended to fit a shut off valve to facilitate
FWD 20
2
the maintenance and a pressure regulator on the water entry for proper operation. The fresh water inlet must be
3
connected to the supply line with a flanges set.
Figure 15 indicates the fresh water inlet for evaporative humidifier sections equipped with a recirculating pump.
The fresh water flow is controlled with a floating valve located into the internal water tank. It is recommended to fit a
shutoff valve on the fresh water inlet to facilitate maintenance. The freshwater inlet must be connected to the supply
line with a flanges set.
The height of the U-trap varies upon the pressure inside the section and is given in mm of water column.
AH-SVX03C-GB
UNT-PRC002-GB
4
1
6
Power level in dB(A), per Hz frequency band
125
250
500
55
50
42
57
54
47
58
57
50
57
51
45
58
54
48
6
60
58
50
1
57
51
45
58
54
48
60
58
50
56
62
50
61
66
55
63
69
58
57
63
51
61
66
55
63
69
58
Power level in dB(A), per Hz frequency band
125
250
500
56
55
55
63
62
60
66
65
63
62
58
55
66
63
60
70
67
63
62
58
55
66
63
60
70
67
63
66
65
65
73
72
69
78
76
73
68
72
64
76
76
68
78
79
71
5
2
1000
2000
37
37
40
30
2
42
32
42
34
45
38
48
40
42
34
45
38
48
40
48
39
3
53
47
56
50
49
40
53
47
56
50
1000
2000
53
46
60
53
62
56
58
51
62
56
65
59
58
51
62
56
65
59
65
57
71
64
75
69
64
56
71
65
74
69
Installation
Overall power
4000
8000
dB(A)
31
30
46
38
40
50
40
43
53
33
28
48
39
35
51
42
39
54
33
28
48
39
35
51
42
39
54
38
36
56
46
45
60
50
49
63
39
37
57
46
45
60
50
49
63
Overall power
4000
8000
dB(A)
45
42
57
53
53
64
55
57
67
48
44
61
55
52
66
59
57
69
48
44
61
55
52
66
59
57
69
50
46
68
59
57
74
64
63
78
52
50
69
61
61
75
66
66
78
11
19