Dry-Well Version With Oil Sensor - Siemens SIMOGEAR BA 2030 Translation Of The Original Operating Instructions

Gearbox
Hide thumbs Also See for SIMOGEAR BA 2030:
Table of Contents

Advertisement

Commissionin g
5.5 Options of the VLplus heavy-duty bearing system
5.5.2

Dry-well version with oil sensor

Please refer to the separate operating instructions for the oil level sensor.
The oil sensor can also be deployed for ATEX version gearboxes.
Functional restriction of the sensor
Note the following:
• The sensor must be free of any dirt and residues.
• Do not damage the cables or the insulation.
• Lay the supply line with strain relief.
• Avoid strong bending loads, buckling and point mechanical loads.
64
ATEX version gearboxes
The oil sensor operates with a disconnector.
The disconnector must be approved for the ATEX version.
The disconnector is installed outside the hazardous area.
Observe the operating instructions of the disconnector.
CAUTION
Operating Instructions, 02/2021, A5E37880173A/RS-AM
BA 2030

Advertisement

Table of Contents
loading

Table of Contents