Gearbox Filled With Operating Oil And Anti-Corrosive Agent; Gearbox Completely Filled With Oil - Siemens SIMOGEAR BA 2535 Mounting And Operating Instructions

Electric monorail gearboxes
Table of Contents

Advertisement

Incoming goods, transport, and storage
5.3 Storage
5.3.2.2

Gearbox filled with operating oil and anti-corrosive agent

NOTICE
Damage to the gearbox caused by incorrect oil quantities
Check the oil level before commissioning.
Observe the information and procedures for Checking the oil level (Page 54).
The gearbox is filled with oil corresponding to the mounting position so that it is ready for
operation, and is sealed airtight using a screw plug or with a pressure breather valve with
transport fixture.
For storage up to 36 months, a VCI anti-corrosion agent (Volatile Corrosion Inhibitor) is
added.
5.3.2.3

Gearbox completely filled with oil

NOTICE
Damage to the gearbox caused by incorrect oil quantities
Prior to commissioning, remove excessive oil until it has the correct oil level.
Observe the information and procedures for Correcting the oil level (Page 54).
When biodegradable oils or oils for the food-processing sector are used, the gearbox is
filled completely with operating oil. The gearbox is closed air-tight with a sealing plug or a
pressure venting with transport fixture.
Do not lower the oil level during short-time commissioning for 10 minutes in no-load
operation.
38
SIMOGEAR electric monorail gearbox
Operating Instructions, 01/2024, A5E53220855A/RS-AA

Advertisement

Table of Contents
loading

Table of Contents