Installing The Sxm2-Gpu Heat Sink - Dell EMC PowerEdge C4140 Installation And Service Manual

Table of Contents

Advertisement

Figure 91. Installing SXM2 GPU
Next steps
1.
Install the SXM2-GPU heat
2.
Install the NVLink air
shroud.

Installing the SXM2-GPU Heat Sink

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in
Steps
1. If you are using an existing SXM2-GPU heat sink, remove the thermal grease from the heat sink by using a clean lint-free
cloth.
2. Using the thermal grease syringe included with your processor kit apply the grease in a thin spiral on the top of the
processor.
CAUTION:
Applying too much thermal grease can result in excess grease coming in contact with and
contaminating the processor socket.
NOTE:
The thermal grease syringe is intended for one-time use only. Dispose the syringe after you use it.
3. Align the screws on the heat sink with the standoffs on the system board.
sink.
Safety instructions
Before working inside your
PowerEdge C4140 installing and removing system components
section.
system.
87