Kenwood NX-200 Service Manual page 92

Hide thumbs Also See for NX-200:
Table of Contents

Advertisement

NX-200
Item
Panel tuning mode
3. Balance
1) Adj item: [BAL]
adjust *2
Adjust: [✳✳✳]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[L BAL]→
[L' BAL]→
[C BAL]→
[H' BAL]→
[H BAL]
Adjust: [✳✳✳]
PTT: ON
Press [ ] key to
store the adjust-
ment value.
Sub LCD:
Tone frequency
[Side1] key: Press
while transmitting
to change 20Hz and
2kHz.
*2: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 102.
Balance adjustment is common with the adjustment of all signaling deviations.
4. Maximum
1) Adj item: [Nn NDEV]
Deviation
Adjust: [✳✳✳✳]
(NXDN)
Deviation meter
adjust *3
LPF: 3kHz
HPF: OFF
[Narrow]
2) Adj item:
[NnL NDEV]→
[NnL' NDEV]→
[NnC NDEV]→
[NnH' NDEV]→
[NnH NDEV]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to
store the adjust-
ment value.
[Very
1) Adj item: [Nv NDEV]
Narrow]
Adjust: [✳✳✳✳]
2) Adj item:
[NvL NDEV]→
[NvL' NDEV]→
[NvC NDEV]→
[NvH' NDEV]→
[NvH NDEV]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to
store the adjust-
ment value.
92
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Balance]
Deviation
Deviation meter
meter
LPF : 3kHz
Oscilloscope
HPF : OFF
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
[2kHz Sine Wave
Check box]: Check
while transmitting
change to 2kHz.
1) Adj item: [Maximum
Deviation
Deviation (NXDN
meter
Narrow)]
Oscilloscope
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation (NXDN
Very Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Panel
ANT
Panel
Adjustment
Specifi cations /
Parts
Method
[Panel
The Deviation of
2kHz Tone deviation
tuning
20Hz frequency is
is within ±1.0% of
mode]
fi xed. Change the
20Hz tone devia-
[
],
2kHz adjustment
tion.
[
]
value to become
the same deviation
[PC test mode]
[PC test
of 20Hz within the
Press [Apply All]
mode]
specifi ed range.
button to store the
[ ],[ ]
adjustment value
after all adjustment
point was adjusted.
[Panel
3056Hz
2995~3117Hz
tuning
mode]
[PC test mode]
[
],
Press [Apply All]
[
]
button to store the
adjustment value
[PC test
after all adjustment
mode]
point was adjusted.
[ ],[ ]
1337Hz
1311~1363Hz
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
point was adjusted.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents