Kenwood NX-200 Service Manual page 114

Hide thumbs Also See for NX-200:
Table of Contents

Advertisement

NX-200
Item
Panel tuning mode
8. Tight
1) Adj item: [An SQLT]
Squelch
Adjust: [✳✳✳]
adjust
2) Adj item:
(Squelch
[AnL SQLT]→
level 9
[AnL' SQLT]→
adjust)
[AnC SQLT]→
[AnH' SQLT]→
[Analog
[AnH SQLT]
Narrow]
Adjust: [✳✳✳]
SSG output: 12dB
SINAD level +5dB
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [Aw
Wide]
SQLT]
Adjust: [✳✳✳]
2) Adj item:
[AwL SQLT]→
[AwL' SQLT]→
[AwC SQLT]→
[AwH' SQLT]→
[AwH SQLT]
Adjust: [✳✳✳]
SSG output: 12dB
SINAD level +5dB
(MOD: 1kHz/±3kHz)
114
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Tight
SSG
Squelch (Analog
Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output: 12dB
SINAD level +5dB
(MOD: 1kHz/±1.5kHz)
1) Adj item: [Tight
Squelch (Analog
Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output: 12dB
SINAD level +5dB
(MOD: 1kHz/±3kHz)
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Universal
connector
Adjustment
Specifi cations /
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Remarks