Kenwood NX-200 Service Manual page 112

Hide thumbs Also See for NX-200:
Table of Contents

Advertisement

NX-200
Item
Panel tuning mode
7. High RSSI
1) Adj item: [An
at –80dBm
HRSSI]
adjust *8
Adjust: [✳✳✳]
2) Adj item:
[Analog
[AnL HRSSI]→
Narrow]
[AnL' HRSSI]→
[AnC HRSSI]→
[AnH' HRSSI]→
[AnH HRSSI]
Adjust: [✳✳✳]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [Aw
Wide]
HRSSI]
Adjust: [✳✳✳]
2) Adj item:
[AwL HRSSI]→
[AwL' HRSSI]→
[AwC HRSSI]→
[AwH' HRSSI]→
[AwH HRSSI]
Adjust: [✳✳✳]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±3kHz)
[NXDN
1) Adj item: [Nv
Very
HRSSI]
Narrow]
Adjust: [✳✳✳]
2) Adj item:
[NvL HRSSI]→
[NvL' HRSSI]→
[NvC HRSSI]→
[NvH' HRSSI]→
[NvH HRSSI]
Adjust: [✳✳✳]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
*8: Because High RSSI at –80dBm (NXDN Narrow) is adjusted by adjusting High RSSI at –80dBm (Analog Narrow), it is not necessary to adjust
High RSSI at –80dBm (NXDN Narrow).
112
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [High
SSG
RSSI (Analog Nar-
row)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High
RSSI (Analog Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±3kHz)
1) Adj item: [High
RSSI (NXDN Very
Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Universal
connector
Adjustment
Specifi cations /
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Adjust with the ana-
log signal.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading