12. Adjust the direction offset of the motion sensor.
The [Reference Direction] mark on the motion sensor should face the ship's bow.
For example, when the mark is skewed 2° in the starboard direction, enter "+2°".
Motion sensor
13. Select [Quit].
14. Press and hold the MENU/ESC key to close the menu.
3.6
How to Set the Stroke of the Hull Unit
According to the stroke (length) of your hull unit, select 800 mm or 1100 mm from the
menu.
1. Press the MENU/ESC key to open the menu.
2. Select [9 Installation Setting].
A confirmation message appears.
3. Select [OK].
4. Select [4 Hull Unit Setting].
5. Select [5 Hull Unit Stroke].
6. Select [800 mm] or [1100 mm].
7. Select [Quit].
8. Press and hold the MENU/ESC key to close the menu.
3.7
How to Configure the Own Ship Mark
To show the own ship mark accurately on-screen, set your ship's dimensions and the
position of the transducer with the following procedure.
1. Press the MENU/ESC key to open the menu.
2. Select [9 Installation Setting].
A confirmation message appears.
3. Select [OK].
4. Select [7 Own Ship Data].
3. ADJUSTMENTS
Quit
Cancel
Menu
Installation Setting
Own Ship Data
1 Ship's Length
: 75m
2 Ship's Width
: 25m
3 TD Position 1
: 15m
4 TD Position 2
: 0.0m
Quit
3-9