1.2.6
How to remount the emergency switch
The emergency switch is attached to the starboard side of the hull unit. If the starboard
side clearance is not sufficient for switch operation, the switch may be remounted on
the port side.
1. Unfasten the four screws to remove the box base.
2. Unfasten the two screws to remove the box cover.
Screw (4 pcs)
Emergency switch
3. Remount the emergency switch to the port side.
Note: For the 800 mm travel hull unit, rotate the emergency switch by 90° so that
the emergency switch cable passes through the rear side of the hull unit (see the
figure at step 4).
4. Secure the emergency switch cable, using the two wiring bands. Wiring band
must be secured to the hull unit, using pan head screws (M4×12).