Air and Water Cooled Installation Manual
Use rigid drain tubes and route them separately –
do not Tee into the bin's drain and, if water cooled,
do not Tee the condenser drain into the reservoir
or bin drain.
Vent the reservoir drain. A vertical vent at the back
of the drain, extended about 200-250 mm will allow
the gravity drain to empty and also keep any
surges during draining from discharging water out
the vent..
Horizontal runs of drain tubing need a 20 mm fall
per meter of run for proper draining.
Follow all applicable codes.

Electrical

The machine is not supplied with a power cord, one
must be field installed. Select the power cord
based on the power draw requirements of the
model being installed.
Water Cooled Shown, Air Cooled Similar
Water
Water Cooled
Supply
Supply
Water
Cooled
Drain
Bin Drain
Connection
Plumbing Connections
The dataplate on the back of the cabinet details the
power requirements, including voltage, phase, and
maximum fuse size. Extension cords are not
permitted. Use of a licensed electrician is
recommended.
Electrical connections are made inside the junction
box in the back panel of the ice machine.
Power Cord Installation:
1. Select and obtain the proper power cord of type
H03RT-F, H05RR-F, H03VV-F, H03VVH2-F or
heavier. Ground wire must be green/yellow color.
Only one cord per plug. See Power Cord
Reference Table for suggested cord sizing.
2. Electrical supply circuit must be dedicated to this
machine. Do not connect to a circuit powering any
other device. Product should only have one supply
means.
3. Remove the junction box cover.
4. Install a field supplied, non-detachable,
non-metalic strain relief per code. Strain relief must
be properly sized for the OD of the power cord and
the ID of the routing hole.
5. Route the power cord through the access hole /
strain relief and properly attach the power supply
Potable
Water
wires. Do not tin the leads. Strip 6 mm of power
Connection
cord lead insulation and properly attach power cord
wires to the lead wires in the junction box.
Drain Vent
6. Connect an electrical plug of the proper type for
Reservoir
the application and country of use.
Drain
Connection
Note: The plug will be the disconnect means for
this machine.
Attach a ground wire to the ground connection in
7.
the junction box. Note: Ground wire must be longer
than power lead wires.
Check voltage when complete.
8.
9. Return the junction box cover to its original
Floor Drain
position and secure with the original screws.
March 2007
Page 8