Scotsman C0530 PRODIGY PLUS Installation And User Manual

Scotsman C0530 PRODIGY PLUS Installation And User Manual

Remote condenser modular cuber prodigy plus e series

Advertisement

Installation and User's Manual for
Remote Condenser Modular Cuber
Prodigy Plus E Series Models C0530, C0630,
C0830 and C1030

Advertisement

Table of Contents
loading

Summary of Contents for Scotsman C0530 PRODIGY PLUS

  • Page 1 Installation and User’s Manual for Remote Condenser Modular Cuber Prodigy Plus E Series Models C0530, C0630, C0830 and C1030...
  • Page 2: Table Of Contents

    C0530E through C1030E Remote Condenser Models - User Manual Introduction The design of this modular remote cuber is the result The Installation section provides the trade person with of years of experience with remote ice machine the information needed to properly install and start refrigeration systems.
  • Page 3: Installation: Product Specifications

    C0530E through C1030E Remote Condenser Models - User Manual Installation: Product Specifications Location Limitations Warranty Information This ice system is made up of three parts, the ice The warranty statement for this product is provided making machine, or head; the remote condenser; and separately from this manual.
  • Page 4: Model Number Description

    Scotsman. Some installations require bin or dispenser adapters. See the table below. Scotsman reserves the right to make design changes and/or improvements at any time. Standard bin applications – Adapter information Specifications and design are subject to change...
  • Page 5: C0530, C0630, C0830 And C1030 Cabinet Dimensions

    C0530E through C1030E Remote Condenser Models - User Manual C0530, C0630, C0830 and C1030 Cabinet Dimensions C0530R, C0630R 10.25 ULTRASONIC 3.25 BIN LEVEL SENSOR 2.00 (OPTIONAL) 2.00 17.8 7.00 48.4 19.05 PLAN VIEW 24.00 REF. REMOTE CONDENSER DISCHARGE LINE 1/2 MALE CPLG. 30.00 REF.
  • Page 6: Product Description And Electrical Requirements

    MAC condensers, kit number is RCKCME6GX. • Fan motor on all the time or controlled to be on whenever the ice machine is operating. • Non-Scotsman condensers must have prior Scotsman Engineering approval for warranty coverage to be in effect. April, 2016 Page 5...
  • Page 7: Water

    Testing has shown that using a filter that does not remove chlorine, such as the Scotsman Aqua Patrol, will greatly improve this situation, while the ice making process itself will remove the chlorine from the ice, resulting in no taste or odor impact.
  • Page 8: Panel Removal

    C0530E through C1030E Remote Condenser Models - User Manual Panel Removal 1. Locate and loosen the two screws at the bottom of the front panel. 2. Pull the front panel out at the bottom and pull it Dataplate down and off the machine. Location 3.
  • Page 9: Remote Condenser Location

    = Calculated Line Length Operating a machine with an unacceptable Configurations that do NOT meet these requirements configuration is misuse and will void the warranty. must receive prior written authorization from Scotsman. 40.35" Remote Condenser Located Condenser Distance & ABOVE Ice Machine Max 35’...
  • Page 10: For The Installer: Remote Condenser

    C0530E through C1030E Remote Condenser Models - User Manual For The Installer: Remote Condenser Locate the condenser as near as possible to the Roof Attachment interior location of the ice machine. Install and attach the remote condenser to the roof Note: The location of the condenser is relative to the of the building, using the methods and practices of ice machine is LIMITED by the specification on the...
  • Page 11: Line Set Routing And Brazing

    C0530E through C1030E Remote Condenser Models - User Manual Line Set Routing and Brazing Do not connect the refrigerant tubing until all 7. Shorten tubing to correct length, clean ends and routing and forming of the tubing is complete. insert them into valve stubs. Final connections requires brazing, steps must Note: Be sure tube and stubs are round, dress with be performed by an EPA certified type II or higher...
  • Page 12: Plumbing Requirements

    C0530E through C1030E Remote Condenser Models - User Manual Plumbing Requirements All models require connection to cold, potable water. 2. Connect drain tubing to drain fitting. A hand actuated valve within site of the machine 3. Route the drain tubing to building drain. Follow is required.
  • Page 13: Electrical

    C0530E through C1030E Remote Condenser Models - User Manual Electrical The machine is not supplied with a power cord, one 1. Remove the junction box cover and route the must either be field installed or the machine hard- power cord through the access hole and properly wired.
  • Page 14: Final Check List

    C0530E through C1030E Remote Condenser Models - User Manual Final Check List: 1. Is the unit located indoors in a controlled environment? Open door to access On and Off switch buttons. 2. Is the unit located where it can receive adequate cooling air? 3.
  • Page 15: Initial Start Up

    C0530E through C1030E Remote Condenser Models - User Manual Initial Start Up 1. Remove front and left side panels. Check machine 6. When the ice has frozen enough, the Ready for for any packing or wires rubbing moving parts. Harvest indicator light will be on steady. After it’s Note location of control board in upper left corner been on steady for a few seconds Harvest will of the machine’s front.
  • Page 16: Adjustments

    C0530E through C1030E Remote Condenser Models - User Manual Adjustments 1/8 - 3/16 “ Bridge Thickness - For the Service Tech Only bridge 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove curtain. 4. Use a hex wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness.
  • Page 17: Use And Operation

    If the De-Scale light is on, the machine has determined that it may need to be cleaned. Contact an authorized Scotsman service agent and have the machine cleaned, de-scaled and sanitized. April, 2016 Page 16...
  • Page 18: Control Switches

    C0530E through C1030E Remote Condenser Models - User Manual Control Switches The On and Off Switches are accessible from the Use of adjustable ice level control front of the machine. There are several positions the ice level can be set to, including Off (knob and label indicators lined up), where it fills the bin until the standard bin control shuts the machine off.
  • Page 19: Cleaning, Sanitation And Maintenance

    10. Locate ice thickness sensor. Squeeze mounting legs together to release sensor. 6. Pour 10 ounces (C0530 or C0630) or 12 ounces (C0830 or C1030) of Scotsman Clear 1 ice machine scale remover into the reservoir. The Push Here unit will circulate the scale remover, then drain to Release and flush it.
  • Page 20 14. Create a solution of sanitizer. Mix 8 ounces of NuCalgon IMS II and 5 gallons of 105-115 degree 2. Mix a solution of 7 ounces Scotsman Clear 1 ice F. potable water to create a 200 ppm active machine scale remover to 84 ounces of potable quaternary solution.
  • Page 21: Remote Condenser

    C0530E through C1030E Remote Condenser Models - User Manual Remote condenser The condenser fins will need to be cleaned. Push and release the Off button. Wait until the machine stops. Note: Lock out the controller or the ice machine power supply to prevent an unauthorized fan motor restart.
  • Page 22: What To Do Before Calling For Service

    C0530E through C1030E Remote Condenser Models - User Manual What to do before calling for service Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. • High discharge temperature.
  • Page 23 SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 17-3599-03...