Resetting the Unit

There are three unit reset modes (numbered 1, 4, and 5), These are available by pressing
the recessed Reset button on the rear panel with a pointed stylus, pen, or similar item to
access it. The following table gives a summary of the reset modes.
ATTENTION:
NOTE: The reset modes listed close all open IP and Telnet connections and sockets.
Mode
Activation
1
Hold in the recessed Reset button for
30 seconds while applying power to the
scaler.
NOTE:
After a mode 1 reset, update
the device with the latest firmware
version. DO NOT operate with the
firmware version that results from this
mode reset. This temporarily resets
the device to factory default until
power is recycled. To use factory
default firmware, upload that version
again.
4
Reset
Hold down the
Reset LED blinks twice (approximately
6 seconds). Then, press
momentarily (<1 second).
5
Reset
Hold down the
Power LED blinks 3 times (approximately
9 seconds). Then, press
momentarily (< 1 second).
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or processor
reboot.
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais mode
de réinitialisation peut causer une perte inattendue de la programmation de la
mémoire flash, une reconfiguration des ports ou une réinitialisation du processeur.
Each mode is a separate function, and not a continuation from mode 1 to mode 5.
DVS 605 Reset Mode Summary
The device reverts to the factory default
firmware.
Firmware reverts to the factory default
for a single power cycle.
All user files and settings (drivers, audio
and video adjustments, IP settings,
and so on) are maintained.
NOTE:
IP settings revert to factory defaults.
button until the
Port mapping reverts to factory default.
Reset
DHCP turns off.
IP address is set to default address
(192.168.254.254).
Reset LED blinks four times in quick
succession during reset.
The device reverts to the factory defaults
button until the
except for firmware.
Reset
Mode 4 results are performed.
All user modifiable configurations reset
to default values including IP settings
and real-time adjustments.
All user loaded files are deleted.
The Reset LED blinks 4 times in quick
succession during the reset
Result
If you do not want to update
the firmware or perform a mode 1
reset by mistake, cycle power to
the device to return to the firmware
version running prior to the reset.
.
Purpose and Notes
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Use mode 4 to reset
all IP settings back to
factory defaults.
Use mode 5 to
restart with default
)
configuration (
.
NOTE:
This reset,
equivalent to the
SIS
EZQQQ}
command, also
removes the initial
serial number
passwords and
sets them to no
password.