Advanced Configuration - Extron electronics DVS 605 Series User Manual

Hide thumbs Also See for DVS 605 Series:
Table of Contents

Advertisement

Audio delay setting
The DVS automatically delays all analog and digital audio inputs to compensate for internal
video processing delay. Occasionally additional audio delay is required to account for other
signal processors, scalers, or display devices in a system. For these situations, the DVS
605 offers an additional 0-255 millisecond static global audio delay which can be set via SIS
command (see
Configuration
page 110) to eliminate audio "lip sync" issues.

Advanced Configuration

The following flowchart provides an overview of the Advanced Configuration submenu
The options are Auto-Image (on or off), aspect ratio (fill or follow), auto memory (on or
off), overscan (none, 2.5%, and 5.0%), switch type (dissolve or cut),
page 25, OSD duration, temperature (device reading only) and factory reset.
ADVANCED
CONFIG
SWITCH TYPE
DISSOLVE
Rotate either to
change switch
type.
Figure 19.
Auto-Image
Use either Adjust knob ([ {) to turn Auto-Image on or off (default).
When enabled and a new input frequency is detected, the DVS first applies an existing
Auto Memory for the signal (if Auto Memory is enabled), or, if no entry exists, performs an
automatic Auto-Image on the new signal. This automatically attempts to size and position
the image to fill the screen, with respect to the current aspect ratio setting.
With Auto-Image disabled, the DVS 605 applies default values to a new input if
Auto Memory is enabled but no Auto Memory exists.
Threshold settings
By default, the Auto-Image function considers any analog video with a >25% brightness
to be active video. Some video sources, such as dark PC backgrounds, or dark borders
around a presentation, may require a lower "Auto-Image threshold," to ensure incoming
video is properly sized and centered by the Auto-Image function. Other scenarios, such
as upstream analog twisted pair extension products, may require a greater Auto-Image
Threshold setting in order to allow the DVS 605 to ignore extraneous sync pulses that may
have been embedded in the RGB signals.
A global analog video Auto-Image threshold value can be set via an SIS command or using
internal web pages.
The range is 0% (black / ~0.0 VDC) to 100% (white / ~0.7 VDC), with a default value of
25%.
NOTE: The Auto-Image threshold setting affects only analog input signals, and has no
effect on digital inputs, which are sized and centered automatically.
Audio delay (available on all models)
on page 89), or internal web pages (see
Next
Next
ASPECT RATIO
AUTO IMAGE
IN#x
Off
IN#x
Rotate either to
turn Auto Image
mode on or off.
Next
Next
TEST PATTERN
OSD DURATION
COLOR BARS
Rotate either to
change test pattern.
Advanced Configuration Menu
on page 49), PCS (see
Audio Settings Page
Test Pattern
Next
Next
AUTO MEMORY
IN#x
ON
FILL
Rotate either to
Rotate either to select
turn auto memory
aspect ratio mode.
on or off.
Next
TEMPERATURE
125 SEC
96 F
35 C
Indicates internal temperature
Rotate either to
(not adjustable).
set OSD duration.
DVS 605 • Operation
Output
on
on
Next
OVERSCAN
S-VIDEO 5.0%
Rotate either to set
overscan value.
Next
FACT. RESET
HOLD AUTO
Press and hold Auto button
to reset unit to factory settings.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvs 605Dvs 605 aDvs 605 dDvs 605 ad

Table of Contents