Resetting the Output Rate

On the front panel, Hold
output image cannot be displayed due to an incompatible output rate, you can use the
front panel buttons to toggle the output rate between 1024x768 @ 60 Hz and
720p @ 60 Hz. To set the rate or toggle between the two available rates:
1.
2.

Locking the Front Panel (Executive Mode)

To prevent access by unauthorized users or accidental changes to the DSC settings, you
can lock the front panel controls by placing the DSC in executive mode. In this mode, all
front panel buttons are disabled and control is available only by the PCS configuration
software or SIS commands.
To lock the front panel, do either of the following:
To unlock the front panel, do either of the following:

Resetting the Unit

Resetting the unit causes various settings to revert to the defaults that were set at
the factory. Resets can be performed from the front panel buttons, the OSD, or SIS
commands. The following resets are available:
NOTE: The Firmware Reset and Factory Reset messages are displayed for 1 minute
for XGA
Ensure that the OSD is closed by pressing and holding the Menu button for 3
seconds.
Press and hold the
button for approximately 5 seconds to toggle between the
VESA and SMPTE rates.
Press and hold the front panel Menu and
message
Executive Mode Enabled
remains on the OSD approximately 2 seconds.
Enter the
SIS command (see the
Enable
commands
on page 30).
Press and hold the front panel Menu and
Executive Mode Disabled
OSD approximately 2 seconds.
Enter the
SIS command (see the
Disable
commands).
Factory defaults: This reset clears all user-specified settings but retains the latest
firmware version. You can perform this reset by:
Selecting
Factory Reset
Factory Reset option
Entering the
Reset all device settings to factory default
command (see the
Reset command
When the reset is complete, the message
Factory firmware: This reset returns the unit to its factory default settings, including
the original firmware with which it was shipped. All user settings are cleared. To
perform this reset, press and hold the Enter button for 20 seconds while applying
power to the unit. When the reset is completed, the message
appears on the OSD.
after the reset to allow time for the display device to sync with the DSC output.
720p is printed above the arrow buttons. If an
/
buttons until the OSD displays the
(approximately 5 seconds). The message
Front Panel Lock (Executive Mode)
buttons again until the OSD displays
(approximately 5 seconds). The message remains on the
Front Panel Lock (Executive Mode)
from the
submenu of the OSD (see the
Advanced
of the
submenu on page 18)
Advanced
on page 30)
Factory Reset
DSC HD-HD • Operation
SIS
is displayed on the OSD.
Firmware Reset