The self-test consists of the following tests:
Test Name
Board level tests
Unit level tests

Port Tests

The Port Tests menu is used to activate testing of specific data
ports. It controls the activation of loopbacks and the initiation of
data test patterns. Test results are displayed in the LCD window.
61200420L1-1
Each of the ESU 120e boards contains an on-
board processor which executes the following
series of tests checking the circuitry on the board:
• RAM tests; EPROM checksum
• TS0 map tests
• On board data path (sending a known test pat-
tern through an on-board loop)
• Front panel LED verification
• Phase-Lock Loop verify
• Board-to-board interface test
A test pattern is sent from the controller through
a loopback on all other boards and is checked on
the controller. This verifies the data path, clocks,
and control signals.
If a failure is detected, note the failure number
prior to contacting ADTRAN Technical Support.
The execution of self-test will disrupt normal
data flow and prevent remote communication
until the self-test is completed.
The execution of Port Tests will disrupt normal data flow in the
port being tested.
ESU 120e User Manual
What it does . . .
Chapter 7. Test Menu
7-7