Chapter 5. Configuration Menu
Normal (CSU) Timing
The typical timing option arrangement is shown in Figure 5-6. The
PBX is looped timed sending data to the ESU 120e which is actually
synchronous to the received data. The Network Interface (NI) is
the actual source of all timings. This timing option is the same as
that typically used for CSUs. This is the preferred mode for use
with a PBX application.
This timing mode works equally well when the PBX is the source of
timing. In that configuration the network would not be providing
timing.