Va Gain Adjustment - Sony BVP-9500WS Maintenance Manual

Color video camera
Hide thumbs Also See for BVP-9500WS:
Table of Contents

Advertisement

3-2. Video Adjustment

3-2-5. VA Gain Adjustment

Equipment:
Waveform monitor
Test Point:
TEST OUT connector/side panel
Object:
Grayscale chart
Notes
. For this adjustment, using an 89.9 % - reflective grayscale chart is preferable. (Refer to Section 3-1-5.)
. Make sure that presetting all the compensation data is completed before beginning adjustment.
(Refer to Section 3-1-4.)
. This adjustment must be done at Field Rate 60 (for BVP-9500WS) or 50 (for BVP-9500WSP) : x1
speed. (Refer to Section 3-1-4.)
Preparations
. Remove the filter disk unit and attach the lens to the CCD unit.
. Connect the waveform monitor to the TEST OUT connector/side panel.
. Setting for MSU-700A MASTER GAIN control block
Master gain → 0 (dB)
. Setting for MSU-700A IRIS control block
Iris → F8.0
. Shoot the grayscale chart so that its frame is aligned with the underscanned monitor frame.
Adjustment procedures
1. G GAIN adjustment
Select G signal by pushing down the TEST OUT switch (side panel) from the RGB position towards
the SEL position. (You can check which signal is selected on the viewfinder screen.)
Adj. point:
1RV2 (G)/VA-189 board
A= 100 ± 2 IRE [NTSC]
Specification:
A= 700 ± 14 mV [PAL]
A
(Waveform monitor)
3-14 (E)
BVP-9500WS/9500WSP MM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-9500wsp

Table of Contents