Technical Data - GEM 4241 Operating Instructions Manual

Combi switchbox
Hide thumbs Also See for 4241:
Table of Contents

Advertisement

7 Technical data

7 Technical data
7.1 Medium
Working medium:
Dust content:
Oil content:
7.2 Temperature
Ambient temperature:
Media temperature:
Storage temperature:
7.3 Pressure
Operating pressure:
Flow rate:
7.4 Product compliance
Machinery Directive:
Explosion protection:
ATEX marking:
IECEx marking:
7.5 Mechanical data
Installation position:
Weight:
Protection class:
Stroke:
GEMÜ 4241
Quality classes to DIN ISO 8573-1
Class 3, max. particle size 5 μm, max. particle density 5 mg/m³
Class 5, max. oil concentration 25 mg/m³
0 to 50 °C
0 to 50 °C
0 to 40 °C
2 to 7 bar
250 Nl/min
The applied pressure must not exceed the maximum control pressure of the process valve.
2006/42/EC
ATEX (2014/34/EU)
Gas:
II 2G Ex ib IIB T4 Gb
Dust:
II 2D Ex ib IIIC T120°C Db
EC type examination certificate: IBExU17ATEX 1160 X
Notified body: IBExU, No. 0637
Gas:
Ex ib IIB T4 Gb
Dust:
Ex IIIC T120°C Db
Certificate: IECEx IBE 19.0017 X
Optional
420 g
IP 65 acc. to EN 60529
IP 67 acc. to EN 60529, is reached with piped air outlet
5 to 75 mm
10 / 27
www.gemu-group.com

Advertisement

Table of Contents
loading

Table of Contents