10.6 Assembling and installing the combi switchbox
Danger of explosion
▶ Danger of death or severe injury.
Do not use the product as a step or foothold.
Prior to commissioning, ensure that the cover is fully closed and that the housing and the O-ring are not
damaged.
1. Move the actuator into the OPEN position.
2. Place the product as far as it will go into the actuator opening, insert adapter 3 (see chapter 9.3) or stroke limiter 1 (see
chapter 9.4) and screw in clockwise against the initial spring tension.
3. Use the spanner flat of the travel sensor to tighten the product.
4. Turn the housing clockwise to align the pneumatic or electrical connections.
5. Set the switch on the product.
Incorrect installation of the product.
▶ Damage to the housing.
Only tighten the product using the spanner flats provided for this purpose.