7.6 Electrical data
7.6.1 2-wire proximity switch (NAMUR)
Supply voltage:
Current consumption:
Electrical connection
type:
7.6.2 Pilot valve
Rated voltage:
Rated power:
Resistance:
Duty cycle:
7.7 Intrinsically safe characteristic values
7.7.1 Proximity switch
Proximity switch:
7.7.2 Pilot valve
Pilot valve, code N1:
Pilot valve, code N2:
www.gemu-group.com
8 V DC
≤ 0.1 A (damped)
≥ 3 mA (undamped)
Connection thread: M16 x 1.5, WAF 19
Cable diameter: 4.5 to 10 mm
Recommended wire cross section: 0.75 mm² x 8 cables
24 V DC ±10 % (code N1)
12 V DC -5/+10 % (code N2)
0.5 W
1152 Ω ± 5 % (code N1)
288 Ω ± 5 % (code N2)
Continuous duty
Ui = 16 V
Ii = 52 mA
Pi = 169 mW
Li = 50 µH
Ci = 30 nF
Ui = 30 V
Ii = 330 mA
Li negligible
Ci negligible
Ui = 30 V
Li negligible
Ci negligible