11 Pneumatic connection
11 Pneumatic connection
11.1 Standard, single acting
Connection
1
Air supply connection P
2
Working connection for process valve A1
3
Venting connection R with silencer (integrated housing ventilation)
1) only relevant for exhaust air duct and/or increase of protection class
11.2 Standard, double acting
Connection
1
Air supply connection P
2
Working connection for process valve A1
3
Venting connection R with silencer (integrated housing ventilation)
4
Working connection for process valve A2
1) only relevant for exhaust air duct and/or increase of protection class
12 Electrical connection
Danger of explosion
▶ Risk of injury or death!
Do not connect or disconnect when connected to the power supply.
●
Do not disconnect the device until the power has been switched off or the area has been classified as non-
●
hazardous.
Danger of explosion
▶ Risk of severe injury or death.
Danger from sparking. Never disconnect the connection cables when live.
●
GEMÜ 4241
Designation
Designation
DANGER
DANGER
20 / 27
Connection size
G 1/8
G 1/8
1)
G 1/8
Connection size
G 1/8
G 1/8
1)
G 1/8
G 1/8
www.gemu-group.com