Technical Data - GEM 4240 Operating Instructions Manual

Combi switchbox
Hide thumbs Also See for 4240:
Table of Contents

Advertisement

7 Technical data

7 Technical data
7.1 Medium
Working medium:
Dust content:
Pressure dew point:
Oil content:
7.2 Temperature
Ambient temperature:
Media temperature:
Storage temperature:
7.3 Pressure
Operating pressure:
Flow rate:
7.4 Product compliance
Machinery Directive:
EMC Directive:
Low Voltage
Directive:
RoHS Directive:
7.5 Mechanical data
Installation position:
Weight:
Protection class:
Travel sensor:
GEMÜ 4240
Quality classes to DIN ISO 8573-1
Class 3, max. particle size 5 μm, max. particle density 5 mg/m³
Size 1
Class 3, max. pressure dew point -20 °C
Size 2
Class 4, max. pressure dew point +3 °C
Size 1
Class 3, max. oil concentration 1 mg/m³
Size 2
Class 5, max. oil concentration 25 mg/m³
0 to 60 °C
0 — 50 °C
-10 — 70 °C
30 — 105 psi
Observe the maximum control pressure of the valve actuator.
250 Nl/min
2006/42/EC
2014/30/EU
(only code N1 and P1)
2014/35/EU
(only code M1)
2011/65/EU
Optional
420 g
IP 65 acc. to EN 60529
IP 67 is achieved by piping away the exhausting air
5 — 75 mm
8 / 23
www.gemu-group.com