Detailed Description Of Messages - Art SGX-NightBass User Manual

Art sgx-nightbass processors: user guide
Table of Contents

Advertisement

DETAILED DESCRIPTION OF MESSAGES

Set Bypass OFF: F0 1A 0x 13 03 00 00 F7
Set Bypass ON: F0 1A 0x 13 03 00 01 F7
This allows remotely setting the state of BYPASS in the NIGHTBASS without
affecting anything else in the unit.
MIDI controller messages may also be used to turn Bypass ON/OFF. The default
value is MIDI controller number 84.
Request DUMP all presets: F0 1A 0x 13 4B F7
LOAD all presets: F0 1A 0x 13 0B <many bytes> F7
Dumps all presets in preset number order.
No compression of the data is done.
Request MPT table: F0 1A 0x 13 4C F7
Set MPT table: F0 1A 0x 13 0C <128 * 2 bytes> F7
For each MIDI program number there is a corresponding NIGHTBASS preset number.
Each entry (internally) is 0..199 and is sent as 2 bytes.
First the least
significant 7 bits, then the msb.
This is done for each of the 128 MIDI program
numbers.
When FX ON/OFF Enable is ON, you may use MIDI controller 84 to activate MIDI
Bypass.
If you find you require additional MIDI technical information, please contact or
Customer Service department at (716) 436-2720.
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents