7 Maintenance
7-1

Preventive Maintenance

Preventive Maintenance covers all actions that prevent downtime.
7-1-1

Preventive Maintenance Schedule

Prevent unscheduled downtime with the following preventive maintenance schedule.
Daily
Check Box PC status
Monitor storage devices that do not
comply to the Omron specifications
Weekly
Clean the Box PC
Ensure you have the latest soft-
ware updates
When changing applications or
configurations
Create a backup of the IPC Ma-
chine Controller
Periodically but at least every 6
months
Check the ambient environment:
Temperature and humidity within
specifications
Noise sources not close to the
Box PC
Check installation:
Box PC mounted secure
Check wiring and connections:
Cable connectors fully inserted
and locked
No damaged wiring or connec-
tors
For a cooling layer with removable
cover:
Check the battery replacement
date on the label at the inside of
the Cover.
Replace the battery before the
replacement date.
Check the backup and repair me-
dia.
7-2
Refer to 3-2 LED Indicators Base Layer on page 3-9 for LED details.
Refer to Storage Device Considerations on page 3-25 for details.
Refer to 7-1-2 Clean the Box PC on page 7-3 for cleaning details.
Refer to the NY-series IPC Machine Controller Industrial Panel PC / In-
dustrial Box PC Setup User's Manual (Cat. No. W568) for update details.
Refer to the NY-series IPC Machine Controller Industrial Panel PC / In-
dustrial Box PC Setup User's Manual (Cat. No. W568) for backup details.
Refer to 4-3 Environmental Specifications on page 4-27 for environmental
specifications.
Refer to 5-3 Mount on page 5-15 for mounting details.
Refer to 5-4 Wire on page 5-27 for wiring details.
Refer to 5-5 Connect on page 5-41 for connection details.
Refer to 7-2-1 Remove the Cover on page 7-4 to check the label.
Refer to 7-2-3 Replace the Battery on page 7-7 to replace the bat-
tery.
Refer to the NY-series IPC Machine Controller Industrial Panel PC / In-
dustrial Box PC Setup User's Manual (Cat. No. W568) for Rescue Disk
details.