Maintenance - Goodman ACNF18 Series Installation Instructions Manual

Ceiling mount air handlers
Table of Contents

Advertisement

BLUE
YELLOW
CEILING MOUNT UNIT
B
W Br
R
I
HEAT PUMP
R
W
2
O
Y
C
*WIRES SUPPLIES WITH HPSK KIT
Note: in case of heat pump failure, switch to "E" on Thermostat for
emergency heat. See note under Low Voltage Wiring
Connect low voltage wires from the thermostat to the corresponding
wires in the Ceiling Mount unit and outdoor unit using No. 18 AWG
wires as follows:
LEAD
THERMOSTAT
RED
R (24V)
GREEN
G (FAN)
-
Y
WHITE
W
BLUE
-
BROWN
E
24 V CONNECTIONS
TO CONDENSING UNIT
R Y G
W
THERMOSTAT
Figure 6
* W
G
C.R.I.
2
4
* W
5
6
1
3
* B
* Y
O
R
Y
E
G W
C
2
THERMOSTAT
Figure 7
NOTES
-
-
TO CONDENSING UNIT
24V CONNECTIONS
-
TO CONDENSING UNIT
24V CONNECTIONS
TO BE USED FOR
EMERGENCY HEAT ONLY
Table 5
CONSTANT TORQUE (EEM) MOTORS
ACNF25 and ACNF31 models utilize constant torque (EEM) motors.
These motors come with a separate control box which is mounted
on the side of the unit as shown in Figure 8. The harness from the
motor is inserted into the control box which has another harness
leading into the control panel of the unit.
The high voltage wiring is the same as the other ACNF models.
The low voltage wiring connections for the ACNF25 and ACNF31
models are shown in Figure 9. The wire from the motor, T2
(purple,) T3 (pink) or T4 (yellow), connects to "Y" from the
thermostat/condenser depending on the application. The rest of
the connections are similar to the other ACNF models.
I

MAINTENANCE

Room Thermostat
The room thermostat controls the operation of your heating and/
or cooling unit. It senses the indoor temperature and signals the
equipment to start or stop maintaining the temperature you have
selected for your comfort. The room thermostat should be in a
central, draft free inside wall location for best operation. Do not place
any heat producing apparatus such as lights, radio, etc., near the
thermostat as this will cause erratic operation of the comfort system.
6
Control Box
Figure 8
Y
R
#18 Gauge
24 VAC
C
R
Y
#18 Gauge
24 VAC
Note: Connect T2,T3 or T4 to the Y
C
Y
terminal to the outdoor unit.
Condensing Unit
CONFIRM SPEED TAP SELECTED (T2, T3, OR T4)
IS APPROPRIATE FOR THE APPLICATION BASED ON THIS TABLE.
BTU
h
WIRE COLOR
18000
PURPLE
24000
PINK
HIGH CFM OPTION
YELLOW
Figure 9
Thermostat
G
W
G
W
T1
T5
Air Handler