Finalizing The Installation; Mv Units Only - Pilot Flame Inspection - (See Instructions; Gsb2 And Gsr2 Units Only - Pilot Flame Inspection - (See Instructions - FireplaceXtrordinair ProBuilder 72 MV Installation Manual

Linear
Table of Contents

Advertisement

44

Finalizing the Installation

1. Remove the glass (see page 48).
NOTE:
If using propane (LP) convert the appliance prior to installing the media.
2. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected
once it enters the firebox, ensuring gas does not build up.
3. GSB2 Versions Only
Install the batteries into the battery holder
GSR2 Versions Only
Install the batteries into the battery box and remote.
4. Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot to verify gas
supply. Leak test all the gas joints. Turn the gas control knob to "OFF" to shut off the appliance.
MV Units Only - Pilot Flame Inspection - (see instructions on page 47)
The pilot flame should look like the illustration below. Adjust the pilot flame if necessary.
GSB2 and GSR2 Units Only - Pilot Flame Inspection - (see instructions on page 47)
The pilot flame should look like the illustration below. Adjust the pilot flame if necessary.
The pilot flame should look like the illustration below. Adjust
the pilot flame if necessary.
To adjust the pilot flame, turn this screw. Clockwise lowers
the flame while counter-clockwise raises it
5. Replace the glass.
© Travis Industries
Installation
(for qualified installers only)
The pilot flame should touch the top 3/8" of the
sensing electrode and make contact with the pilot
hood. Adjust the pilot up or down as necessary.
Sensing
electrode
4/22/21 - 1458
Pilot Hood
Spark
Electrode
PB 72 MV/GSB2/GSR2 Install