Intellex
72
Alarm Setup
Digital Video Management System Installation and Operating Instructions
the Utility Options screen. Otherwise, alarm messages remain on
the screen until either the duration time expires or the event is
cleared.
Unit Alarm Out — Use this option to energize alarm output 16
whenever any alarm event occurs. Otherwise, the unit only
energizes alarm output 16 whenever an alarm event occurs on
camera 16.
Message Alert — Use this option to energize alarm output 16
when the unit is in linear mode and a notification screen appears.
NOTE: The Alarms indicator on the front panel flashes and
cannot be disabled.
Quality — Select the record quality to use when an alarm occurs.
The default setting is Normal.
Super — Record images at the highest image quality. Since
the unit uses the lowest level of compression, this setting
requires the highest amount of storage space.
Normal — Record images at normal image quality. This
setting provides a balance between compression and storage
space requirements.
Extended Record — Record images at the highest level of
compression. This setting requires the lowest amount of
storage space.
Sensitivity — This setting lets you control how Intellex responds
to small, subtle changes between images. Select the sensitivity to
use during an alarm event. The default is Normal.
High — At this setting, Intellex records the smaller changes
between images, improving the perceived picture quality. As
a result, this setting requires more storage space.