Database 90% Full
When the percentage of unarchived images in the image database
reaches 90%, the unit flashes the Alarms indicator on the front
panel. It also energizes alarm output 16 if the Message Alert
option is selected (see
Alarm
Setup). Then it displays the
following screen:
NOTE: This screen only appears when Linear is selected on the
Record Mode screen.
Select one of the following options and click OK:
Halt when database is full. — Select this option to halt image
recording when the image database is full.
You must click the Begin Record button on the Utility Options
screen to start recording again (see
Utility
Options).
Notify me again when 90% full. — This option is disabled when
the image database is at least 90% full.
Continue at beginning when full. — Select this option to
continue recording images from the beginning of the image
database. When the database becomes full, the unit behaves as if
circular mode is selected, recording over the oldest images.
Help — Click to display online help for the screen.
Linear Mode Operation